H Higuchi1, Y Adachi, H Wada, M Kanno, T Satoh. 1. Department of Anaesthesia, Self Defense Force Central Hospital, Setagaya, Tokyo, Japan. higu-chi@ka2.so-net.ne.jp
Abstract
BACKGROUND: We evaluated the effect of low-flow sevoflurane anaesthesia, in which compound A is generated, and isoflurane anaesthesia, in which compound A is not generated (n=13 in each group), on hepatocellular integrity using alpha glutathione S-transferase (GST). Alpha GST is a more sensitive and specific marker of hepatocellular damage than is aminotransferase activity and correlates better with hepatic histology. METHODS:Sevoflurane or isoflurane were delivered without nitrous oxide with a fresh gas flow of 1 l/min. Concentrations of compound A in the circuit were measured hourly, and plasma alpha GST concentrations were measured perioperatively. RESULTS:Mean duration of anaesthesia was 338+/-92 min in the sevoflurane group and 320+/-63 min in the isoflurane group. Mean compound A concentration in the sevoflurane group was 28.6+/-9.0 ppm. There was no significant difference in alpha GST concentrations between the sevoflurane and isoflurane groups during or after anaesthesia. CONCLUSION: These results indicate that low-flow sevoflurane and isoflurane anaesthesia have the same effect on hepatic function, as assessed by plasma alpha GST concentrations.
RCT Entities:
BACKGROUND: We evaluated the effect of low-flow sevoflurane anaesthesia, in which compound A is generated, and isoflurane anaesthesia, in which compound A is not generated (n=13 in each group), on hepatocellular integrity using alpha glutathione S-transferase (GST). Alpha GST is a more sensitive and specific marker of hepatocellular damage than is aminotransferase activity and correlates better with hepatic histology. METHODS:Sevoflurane or isoflurane were delivered without nitrous oxide with a fresh gas flow of 1 l/min. Concentrations of compound A in the circuit were measured hourly, and plasma alpha GST concentrations were measured perioperatively. RESULTS: Mean duration of anaesthesia was 338+/-92 min in the sevoflurane group and 320+/-63 min in the isoflurane group. Mean compound A concentration in the sevoflurane group was 28.6+/-9.0 ppm. There was no significant difference in alpha GST concentrations between the sevoflurane and isoflurane groups during or after anaesthesia. CONCLUSION: These results indicate that low-flow sevoflurane and isoflurane anaesthesia have the same effect on hepatic function, as assessed by plasma alpha GST concentrations.
Authors: Alexander Choukér; André Martignoni; Rolf J Schauer; Martin Dugas; Thomas Schachtner; Ines Kaufmann; Florian Setzer; Horst G Rau; Florian Löhe; Karl W Jauch; Klaus Peter; Manfred Thiel Journal: World J Surg Date: 2005-04 Impact factor: 3.352