Literature DB >> 11732785

Contamination of gowns, gloves, and stethoscopes with vancomycin-resistant enterococci.

K C Zachary1, P S Bayne, V J Morrison, D S Ford, L C Silver, D C Hooper.   

Abstract

OBJECTIVE: [corrected] To measure directly the rate of contamination, during routine patient examination, of gowns, gloves, and stethoscopes with vancomycin-resistant enterococci (VRE).
SETTING: A large, academic, tertiary-care hospital. PATIENTS: Between January 1997 and December 1998, 49 patients colonized or infected with VRE were entered in the study.
DESIGN: After routine examination, the examiner's glove fingertips, gown (the umbilical region and the cuffs), and stethoscope diaphragm were pressed onto Columbia colistin-nalidixic acid (CNA) agar plates with 5% sheep blood plus vancomycin 6 pg/mL. The stethoscope diaphragm was sampled again after cleaning with a 70% isopropanol wipe.
RESULTS: VRE were isolated from at least 1 examiner site (gloves, gowns, or stethoscope) in 33 (67%) of 49 cases. Gloves were contaminated in 63%, gowns in 37%, and stethoscopes in 31%. All three items were positive for VRE in 24%. One case each had stethoscope and gown contamination without glove contamination. Only 1 (2%) of 49 stethoscopes was positive after wiping with an alcohol swab. Contamination at any site was more likely when the patient had a colostomy or ileostomy. Patients identified by rectal-swab culture alone were as likely to contaminate their examiners as were those identified by clinical specimens.
CONCLUSIONS: Our study revealed a high rate of examiner contamination with VRE. The similar risk of contamination identified by surveillance and clinical cases reinforces concerns that patients not known to be colonized with VRE could serve as sources for dissemination. Wiping with alcohol is effective in decontaminating stethoscopes.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11732785     DOI: 10.1086/501952

Source DB:  PubMed          Journal:  Infect Control Hosp Epidemiol        ISSN: 0899-823X            Impact factor:   3.254


  29 in total

1.  Microbial colonization of electrocardiographic telemetry systems before and after cleaning.

Authors:  Alice Reshamwala; Kathryn McBroom; Yong Il Choi; Linda LaTour; Antoinette Ramos-Embler; Rowena Steele; Virginia Lomugdang; Margaret Newman; Colleen Reid; Yanfang Zhao; Bradi B Granger
Journal:  Am J Crit Care       Date:  2013-09       Impact factor: 2.228

2.  2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care Settings.

Authors:  Jane D Siegel; Emily Rhinehart; Marguerite Jackson; Linda Chiarello
Journal:  Am J Infect Control       Date:  2007-12       Impact factor: 2.918

3.  [Prevention and control of the spread of vancomycin-resistant enterococci: results of a workshop held by the German Society for Hygiene and Microbiology].

Authors:  R-P Vonberg; I F Chaberny; A Kola; F Mattner; S Borgmann; M Dettenkofer; D Jonas; A-M Fahr; I Klare; G Werner; K Weist; C Wendt; P Gastmeier
Journal:  Anaesthesist       Date:  2007-02       Impact factor: 1.041

Review 4.  Gloves, gowns and masks for reducing the transmission of meticillin-resistant Staphylococcus aureus (MRSA) in the hospital setting.

Authors:  Jesús López-Alcalde; Marta Mateos-Mazón; Marcela Guevara; Lucieni O Conterno; Ivan Solà; Sheila Cabir Nunes; Xavier Bonfill Cosp
Journal:  Cochrane Database Syst Rev       Date:  2015-07-16

5.  White coats as a vehicle for bacterial dissemination.

Authors:  Asima Banu; Mridu Anand; Nagarjun Nagi
Journal:  J Clin Diagn Res       Date:  2012-10

6.  Comparison of tissue damage, cleansing and cross-contamination potential during wound cleansing via two methods: lavage and negative pressure wound therapy with instillation.

Authors:  Diwi Allen; Lori A LaBarbera; Ioana L Bondre; M Christian Lessing; Anthony M Rycerz; Deepak V Kilpadi; Barbara A Collins; Joanna Perkins; Amy K McNulty
Journal:  Int Wound J       Date:  2012-08-21       Impact factor: 3.315

Review 7.  Controlling hospital-acquired infection: focus on the role of the environment and new technologies for decontamination.

Authors:  Stephanie J Dancer
Journal:  Clin Microbiol Rev       Date:  2014-10       Impact factor: 26.132

8.  Methicillin and Vancomycin Resistant S. aureus in Hospitalized Patients.

Authors:  Poonam Sood Loomba; Juhi Taneja; Bibhabati Mishra
Journal:  J Glob Infect Dis       Date:  2010-09

9.  Rapid curbing of a vancomycin-resistant Enterococcus faecium outbreak in a nephrology department.

Authors:  Aude Servais; Lucile Mercadal; Florence Brossier; Marcia Venditto; Belkacem Issad; Corinne Isnard-Bagnis; Gilbert Deray; Jérôme Robert
Journal:  Clin J Am Soc Nephrol       Date:  2009-08-27       Impact factor: 8.237

10.  Epidemiology and control of an outbreak of vancomycin-resistant enterococci in the intensive care units.

Authors:  Young Kyung Yoon; Hee Sun Sim; Jeong Yeon Kim; Dae Won Park; Jang Wook Sohn; Kyung Ho Roh; Seung Eun Lee; Min Ja Kim
Journal:  Yonsei Med J       Date:  2009-10-21       Impact factor: 2.759

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.