Literature DB >> 11730342

A quantitative method to measure telomerase activity by bioluminescence connected with telomeric repeat amplification protocol.

S Xu1, M He, H Yu, X Cai, X Tan, B Lu, B Shu.   

Abstract

Telomerase is expected to be a new biomarker for cancer diagnosis. The telomeric repeat amplification protocol (TRAP) is a sensitive method to detect telomerase activity. However, TRAP and its modified protocols are not always suitable for measuring telomerase activity of a large number of clinical samples to diagnosis cancer because these methods generally require a time-consuming detection step such as gel electrophoresis. To improve the procedure for mass diagnosis, we applied bioluminescence to replace the detection step. Telomerase activity is measured by evaluating the amount of inorganic pyrophosphate generated in PCR amplification of telomerase elongation product, with use of the sensitive enzymatic luminometric inorganic pyrophosphate detection assay (ELIDA). TRAP connected with ELIDA (TRAP-ELIDA) can quantitatively detect telomerase activity within linearity from 2 to 1000 cell equivalents. The ELIDA signals accorded with results of TRAP-SYBR green staining, and the results of ELIDA were significantly correlated to those of TRAP connected with an enzyme-linked immunosorbent assay (TRAP-ELISA) (r(2) = 0.992, P < 0.001). TRAP-ELIDA is a simple and sensitive method to quantify telomerase activity without time-consuming gel electrophoresis. Because TRAP-ELIDA measures telomerase activity with a luminometer, it could be applied to a large number of clinical samples at the same time. (c)2001 Elsevier Science.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11730342     DOI: 10.1006/abio.2001.5418

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  7 in total

1.  Highly selective fluorescent recognition of pyrophosphate in water by a new chemosensing ensemble.

Authors:  Lijun Tang; Minghui Liu; Fangfang Li; Raju Nandhakumar
Journal:  J Fluoresc       Date:  2010-10-30       Impact factor: 2.217

2.  A pyrrolyl-based triazolophane: a macrocyclic receptor with CH and NH donor groups that exhibits a preference for pyrophosphate anions.

Authors:  Jonathan L Sessler; Jiajia Cai; Han-Yuan Gong; Xiaoping Yang; Jonathan F Arambula; Benjamin P Hay
Journal:  J Am Chem Soc       Date:  2010-10-13       Impact factor: 15.419

3.  SYBR Green real-time telomeric repeat amplification protocol for the rapid quantification of telomerase activity.

Authors:  Henning Wege; Michael S Chui; Hai T Le; Julie M Tran; Mark A Zern
Journal:  Nucleic Acids Res       Date:  2003-01-15       Impact factor: 16.971

Review 4.  'Borono-lectin' based engineering as a versatile platform for biomedical applications.

Authors:  Akira Matsumoto; Yuji Miyahara
Journal:  Sci Technol Adv Mater       Date:  2017-12-19       Impact factor: 8.090

5.  Selective Detection of Pyrophosphate Anions in Aqueous Medium Using Aggregation of Perylene Diimide as a Fluorescent Probe.

Authors:  Sucharita Dey; Pradip Kr Sukul
Journal:  ACS Omega       Date:  2019-09-20

Review 6.  The Impact of Exercise on Telomere Length, DNA Methylation and Metabolic Footprints.

Authors:  Sandra Haupt; Tobias Niedrist; Harald Sourij; Stephan Schwarzinger; Othmar Moser
Journal:  Cells       Date:  2022-01-04       Impact factor: 6.600

Review 7.  The Multifarious Applications of Copper Nanoclusters in Biosensing and Bioimaging and Their Translational Role in Early Disease Detection.

Authors:  Kumar Babu Busi; Mathangi Palanivel; Krishna Kanta Ghosh; Writoban Basu Ball; Balázs Gulyás; Parasuraman Padmanabhan; Sabyasachi Chakrabortty
Journal:  Nanomaterials (Basel)       Date:  2022-01-18       Impact factor: 5.076

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.