The index of motor current amplitude has feasibility in control for continuous flow pumps and evaluation of left ventricular function.

G Endo1, K Araki, K Kojima, K Nakamura, Y Matsuzaki, T Onitsuka.   

Abstract

The index of motor current amplitude (ICA) has feasibility in continuous-flow ventricular assist device control. It can demonstrate the safe range of pump speed, which exists between the starting point of total assistance (t-point) and the starting point of sucking (s-point). The objective of this study was to investigate how the ICA characteristic curve changes with each condition of contractility, preload, and afterload changes. We changed preload, afterload, and contractility of closed-mock circulation and plotted the change of the ICA value against pump speed. Then the shift of ICA characteristic curve against the change of each condition was considered. When preload increased, ICA characteristic curves showed the expansion of a safe range. When afterload increased, ICA characteristic curves were shifted to the high rotation side, slightly narrowing a safe range. When contractility increased, ICA characteristic curves showed the shift of a convex above to narrowing of a safe range. As these shift patterns were observed even when the driving conditions of a circuit changed, reproducibility was checked. Understanding the feature of a shift pattern of ICA characteristic curves correctly, a possibility that change of the heart function could be predicted by change of ICA value and a possibility for a flexible control method based on ICA, according to hemodynamic state, were suggested.

Entities:  

Mesh:

Year:  2001        PMID: 11722345     DOI: 10.1046/j.1525-1594.2001.06859.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  3 in total

1.  Mechanical circulatory support device-heart hysteretic interaction can predict left ventricular end diastolic pressure.

Authors:  Brian Y Chang; Steven P Keller; Sonya S Bhavsar; Noam Josephy; Elazer R Edelman
Journal:  Sci Transl Med       Date:  2018-02-28       Impact factor: 17.956

2.  A Scalable Approach to Determine Intracardiac Pressure From Mechanical Circulatory Support Device Signals.

Authors:  Brian Y Chang; Christian Moyer; Ahmad El Katerji; Steven P Keller; Elazer R Edelman
Journal:  IEEE Trans Biomed Eng       Date:  2021-02-18       Impact factor: 4.538

3.  Hysteretic device characteristics indicate cardiac contractile state for guiding mechanical circulatory support device use.

Authors:  Brian Y Chang; Zhengyang Zhang; Steven P Keller; Elazer R Edelman; Kimberly Feng; Noam Josephy
Journal:  Intensive Care Med Exp       Date:  2021-12-20
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.