BACKGROUND: The Maze procedure restores atrial fibrillation to normal sinus rhythm. However, concurrent left atrial functional recovery is not always achieved. To address this limitation, a modification using linear cryoablation is described. METHODS: Between July 1997 and December 1999, 83 patients received atrial fibrillation surgery in association with mitral valve surgery with or without additional concurrent procedures by either the conventional technique, group I (n = 30) or the modified technique, group II (n = 53). Onset of sinus conversion and echocardiographic assessment of postoperative left ventricular function, left atrial size, and mitral A-wave velocity were compared in the early postoperative period and 6 months after surgery. RESULTS: Sinus conversion occurred significantly earlier in group II, 2.4 +/- 5 days versus group I, 7.0 +/- 10 days. The mean transmitral A-wave velocity and the incidence of A-wave appearance in the early postoperative period and 6 months postoperatively were greater in group II than group I. CONCLUSIONS: With the current modification, restoration of sinus rhythm and superior left atrial contractile function occurred earlier than with the standard Maze III technique.
BACKGROUND: The Maze procedure restores atrial fibrillation to normal sinus rhythm. However, concurrent left atrial functional recovery is not always achieved. To address this limitation, a modification using linear cryoablation is described. METHODS: Between July 1997 and December 1999, 83 patients received atrial fibrillation surgery in association with mitral valve surgery with or without additional concurrent procedures by either the conventional technique, group I (n = 30) or the modified technique, group II (n = 53). Onset of sinus conversion and echocardiographic assessment of postoperative left ventricular function, left atrial size, and mitral A-wave velocity were compared in the early postoperative period and 6 months after surgery. RESULTS: Sinus conversion occurred significantly earlier in group II, 2.4 +/- 5 days versus group I, 7.0 +/- 10 days. The mean transmitral A-wave velocity and the incidence of A-wave appearance in the early postoperative period and 6 months postoperatively were greater in group II than group I. CONCLUSIONS: With the current modification, restoration of sinus rhythm and superior left atrial contractile function occurred earlier than with the standard Maze III technique.
Authors: Anson M Lee; Kal Clark; Marci S Bailey; Abdulhameed Aziz; Richard B Schuessler; Ralph J Damiano Journal: Innovations (Phila) Date: 2010 Jul-Aug
Authors: Li Poa; Miguel Puig; Pablo Zubiate; Edward Ranzenbach; Miller Shari-Knutson; Christina Poa; Hyunah Poa Journal: J Atr Fibrillation Date: 2009-08-01