BACKGROUND: Atrial transport and atrial natriuretic peptide secretion is severely reduced from normal after the maze III procedure. To improve these factors, we developed a bilateral appendage-preserving maze procedure (BAP-maze). METHODS: Forty-six patients with chronic atrial fibrillation who underwent the BAP-maze procedure were compared with 40 patients who underwent the maze III procedure. The ratio of the peak velocity of the A and E waves of transmitral flow (transthoracic pulsed Doppler echocardiography), the left atrial appendage ejection fraction (transesophageal echocardiography), and the atrial natriuretic peptide secretory reserve during treadmill exercise test were measured at 6 months postoperatively. RESULTS: Sinus rhythm was restored in 44 patients (95.7%) by the BAP-maze procedure and in 39 patients (97.5%) by the maze III procedure. The ratio of the peak velocity of the A and E waves was 0.52 +/- 0.22 in the BAP-maze group and 0.25 +/- 0.19 in the maze III group (p < 0.0001). The left atrial appendage ejection fraction was 44.7% +/- 11.5%, and the atrial natriuretic peptide secretory reserve was greater in the BAP maze group (p = 0.037). CONCLUSIONS: The BAP-maze procedure improved atrial transport and atrial natriuretic peptide secretion as well as simplifying the maze operation, without decreasing its effectiveness against atrial fibrillation.
BACKGROUND: Atrial transport and atrial natriuretic peptide secretion is severely reduced from normal after the maze III procedure. To improve these factors, we developed a bilateral appendage-preserving maze procedure (BAP-maze). METHODS: Forty-six patients with chronic atrial fibrillation who underwent the BAP-maze procedure were compared with 40 patients who underwent the maze III procedure. The ratio of the peak velocity of the A and E waves of transmitral flow (transthoracic pulsed Doppler echocardiography), the left atrial appendage ejection fraction (transesophageal echocardiography), and the atrial natriuretic peptide secretory reserve during treadmill exercise test were measured at 6 months postoperatively. RESULTS: Sinus rhythm was restored in 44 patients (95.7%) by the BAP-maze procedure and in 39 patients (97.5%) by the maze III procedure. The ratio of the peak velocity of the A and E waves was 0.52 +/- 0.22 in the BAP-maze group and 0.25 +/- 0.19 in the maze III group (p < 0.0001). The left atrial appendage ejection fraction was 44.7% +/- 11.5%, and the atrial natriuretic peptide secretory reserve was greater in the BAP maze group (p = 0.037). CONCLUSIONS: The BAP-maze procedure improved atrial transport and atrial natriuretic peptide secretion as well as simplifying the maze operation, without decreasing its effectiveness against atrial fibrillation.
Authors: Shun Ijuin; Ali Hamadanchi; Franz Haertel; Laura Baez; Paul Christian Schulze; Marcus Franz; Sven Moebius-Winkler Journal: J Cardiovasc Echogr Date: 2020-04-13
Authors: Jason O Robertson; Anson M Lee; Rochus K Voeller; Marci S Damiano; Richard B Schuessler; Ralph J Damiano Journal: Eur J Cardiothorac Surg Date: 2014-02-11 Impact factor: 4.191