An antibody-immobilized capillary column as a bioseparator/bioreactor for detection of Escherichia coil O157:H7 with absorbance measurement.

Y Liu1, Y Li.   

Abstract

A capillary-column-based bioseparator/bioreactor was developed for detection of Escherichia coli O157:H7 by chemically immobilizing anti-E. coli O157:H7 antibodies onto the inner wall of the column, forming the "sandwich" immunocomplexes (immobilized antibody-E. coli O157: H7-enzyme-labeled antibody) after the sample and the enzyme-labeled antibody passed through the column and detecting the absorbance of the product in the bioreactor with an optical detector. The effects of the blocking agent, flow rate of samples and substrates, buffer, MgCl2, and pH on the detection of E. coli O157:H7 were investigated. The parameters, 2% BSA in 1.0 x 10-2 M, pH 7.4, PBS as the blocking agent, 0.5 mL/h as the sample flow rate, 1.0 x 10(-2) M MgCl2, and 2.0 x 10(-4) M p-nitrophenyl phosphate in 1.0 M, pH 9.0 Tris buffer as the substrate for the enzymatic reaction, and 1.0 mL/h as the substrate flow rate, were used in the bioseparator/bioreactor system for detection of E. coli O157:H7. The selectivity of the system was checked, and other pathogens, including Salmonella typhimurium, Campylobacterjejuni, and Listeria monocytogenes, had no interference with the detection of E. coli O157:H7. Its working range was from 5.0 x 10(2) to 5.0 x 10(6) cfu/mL, and the total assay time was < 1.5 h without any enrichment. The relative standard deviation was approximately 2.0-7.3%.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11721916     DOI: 10.1021/ac0104936

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Detection of pathogens using luminescent CdSe/ZnS dendron nanocrystals and a porous membrane immunofilter.

Authors:  Yongcheng Liu; Robert Brandon; Michael Cate; Xiaogang Peng; Robert Stony; Michael Johnson
Journal:  Anal Chem       Date:  2007-10-17       Impact factor: 6.986

2.  Sensing Escherichia coli O157:H7 via frequency shift through a self-assembled monolayer based QCM immunosensor.

Authors:  Li-jiang Wang; Chun-sheng Wu; Zhao-ying Hu; Yuan-fan Zhang; Rong Li; Ping Wang
Journal:  J Zhejiang Univ Sci B       Date:  2008-02       Impact factor: 3.066

3.  FTIR nanobiosensors for Escherichia coli detection.

Authors:  Stefania Mura; Gianfranco Greppi; Maria Laura Marongiu; Pier Paolo Roggero; Sandeep P Ravindranath; Lisa J Mauer; Nicoletta Schibeci; Francesco Perria; Massimo Piccinini; Plinio Innocenzi; Joseph Irudayaraj
Journal:  Beilstein J Nanotechnol       Date:  2012-07-03       Impact factor: 3.649

Review 4.  Portable Nanoparticle-Based Sensors for Food Safety Assessment.

Authors:  Gonca Bülbül; Akhtar Hayat; Silvana Andreescu
Journal:  Sensors (Basel)       Date:  2015-12-05       Impact factor: 3.576