Literature DB >> 11709470

Total body irradiation using a modified standing technique: a single institution 7 year experience.

S V Harden1, D S Routsis, A R Geater, S J Thomas, C Coles, P J Taylor, R E Marcus, M V Williams.   

Abstract

We describe a simple standing technique for delivering total body irradiation (TBI) using large horizontal fields, made possible by the off-centre installation of a non-dedicated treatment unit in a pre-existing bunker. Patients are treated using anterior and posterior fields with customized lung compensators. This technique enables the dose to the lung to be accurately calculated and modified to avoid overdose and to minimize the risk of pneumonitis. From February 1991 to December 1997, 94 patients with a variety of haematological malignancies were given fractionated TBI using this technique prior to allogenic or autologous bone marrow transplantation. Patients received a total dose of 14.4 Gy given in eight fractions over 4 days, with at least 6 h between fractions. The prescribed dose to the lungs was reduced to 12 Gy in eight fractions. The technique was well tolerated, took less than 10 min to set up and did not disrupt the daily routine use of the machine. Doses to all measured points on the trunk and head were within +/-6% of the prescribed dose. Doses to the lungs were within +/-5% of the prescribed dose. There were no early respiratory deaths in the 37 autologous transplant patients. There were 10 (17%) respiratory deaths in the 57 allogeneic transplant patients, 3 of confirmed infectious aetiology.

Entities:  

Mesh:

Year:  2001        PMID: 11709470     DOI: 10.1259/bjr.74.887.741041

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  6 in total

1.  Dosimetry and verification of Co total body irradiation with human phantom and semiconductor diodes.

Authors:  Mahmoud Allahverdi; Ghazale Geraily; Mahbod Esfehani; Aliakbar Sharafi; Peyman Haddad; Alireza Shirazi
Journal:  J Med Phys       Date:  2007-10

2.  Evaluation of Dose Distribution in Optimized Stanford Total Skin Electron Therapy (TSET) Technique in Rando Anthropomorphic Phantom using EBT3 Gafchromatic Films.

Authors:  Shaghayegh Fahimi Monzari; Ghazale Geraily; Mehdi Aghili; Heydar Toolee
Journal:  J Biomed Phys Eng       Date:  2021-08-01

Review 3.  Pulmonary Toxicity After Total Body Irradiation - Critical Review of the Literature and Recommendations for Toxicity Reporting.

Authors:  Jennifer Vogel; Susanta Hui; Chia-Ho Hua; Kathryn Dusenbery; Premavarthy Rassiah; John Kalapurakal; Louis Constine; Natia Esiashvili
Journal:  Front Oncol       Date:  2021-08-26       Impact factor: 6.244

4.  Correlation of plasma FL expression with bone marrow irradiation dose.

Authors:  Mary Sproull; Dane Avondoglio; Tamalee Kramp; Uma Shankavaram; Kevin Camphausen
Journal:  PLoS One       Date:  2013-03-07       Impact factor: 3.240

5.  In vivo dosimetry for total body irradiation: five-year results and technique comparison.

Authors:  Reshma P Patel; Alison J Warry; David J Eaton; Christopher H Collis; Ivan Rosenberg
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

6.  Total Body Irradiation for Hematopoietic Stem Cell Transplantation: What Can We Agree on?

Authors:  Mitchell Sabloff; Steven Tisseverasinghe; Mustafa Ege Babadagli; Rajiv Samant
Journal:  Curr Oncol       Date:  2021-02-14       Impact factor: 3.677

  6 in total