Literature DB >> 11703204

Induction of labor in women with previous cesarean section using the double balloon device.

S Khotaba1, M Volfson, L Tarazova, M Odeh, R Barenboym, V Fait, E Ophir, M Oettinger.   

Abstract

BACKGROUND AND METHODS: To evaluate the efficacy and safety of labor induction by the double balloon device in women with previous cesarean section. Induction of labor was carried out in 37 women with previous cesarean section for various indications. All the inductions of labor were performed using the Atad double balloon device (ARD).
RESULTS: Cervical ripening (Bishop scores above 5) was achieved in 82.3% of the induced women with subsequent vaginal delivery in 78.6% and repeat cesarean section in 22.3%. An important observation of the results was the chances to achieve a vaginal delivery according to the second Bishop score that was recorded 12 hours following the insertion of the device. When the second was above 5 the chances for vaginal delivery were 79.4%. The mean time from removal of the device to delivery was 10.8 hours. No complications were noted using the device.
CONCLUSIONS: The double balloon device appears to be a safe and effective method of inducing labor in women with a previous lower segment cesarean section. Wide scale studies and further use of the device for induction of labor in women who have had previous cesarean sections are warranted.

Entities:  

Mesh:

Year:  2001        PMID: 11703204     DOI: 10.1034/j.1600-0412.2001.801114.x

Source DB:  PubMed          Journal:  Acta Obstet Gynecol Scand        ISSN: 0001-6349            Impact factor:   3.636


  1 in total

1.  Double-balloon catheter for induction of labour in women with a previous cesarean section, could it be the best choice?

Authors:  Carlos De Bonrostro Torralba; Eva Lucía Tejero Cabrejas; Sabina Marti Gamboa; María Lapresta Moros; Jose Manuel Campillos Maza; Sergio Castán Mateo
Journal:  Arch Gynecol Obstet       Date:  2017-03-18       Impact factor: 2.344

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.