Literature DB >> 11702965

Medpor porous polyethylene implants in orbital blowout fracture repair.

S G Ng1, S A Madill, C F Inkster, A J Maloof, B Leatherbarrow.   

Abstract

PURPOSE: Various materials are used in orbital blowout fracture repair. We describe a series of patients with orbital blowout fractures that were repaired using porous polyethylene (Medpor) sheets.
METHODS: A non-comparative interventional case series is described of 30 blowout fractures of 30 patients aged 7-60 years (median 29 years) who underwent orbital blowout fracture repair with Medpor sheets. The mean follow-up was 19.1 months (minimum 5 months). The indication for surgery in 6 cases was non-resolving diplopia. The remaining 24 cases had surgery for enophthalmos. Ten cases underwent primary or secondary hydroxyapatite orbital implantation at the same time as orbital floor blowout fracture repair. Data were collected on postoperative motility and diplopia, enophthalmos, cosmesis, complications and re-operations.
RESULTS: In no case was diplopia worsened by blowout fracture repair. Where surgery was performed for the correction of enophthalmos, late surgery did not compromise the surgical results. There were no intraoperative complications. The one major complication was a case of recurrent implant infections leading to implant removal. There were 3 minor postoperative complications: 2 cases of postoperative infraorbital anaesthesia and one case of a palpable titanium screw. Re-operations were performed for pre-existent diplopia, lid laxity, socket abnormalities and mid-facial deformities. None of these arose from the blowout fracture repair.
CONCLUSIONS: The study suggests that in orbital blowout fracture repair Medpor implants are safe and effective with few complications. Late surgery for enophthalmos is technically more difficult but is not associated with poorer functional or cosmetic results.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11702965     DOI: 10.1038/eye.2001.188

Source DB:  PubMed          Journal:  Eye (Lond)        ISSN: 0950-222X            Impact factor:   3.775


  11 in total

1.  Porous polyethylene implants in orbital floor reconstruction.

Authors:  I-Chan Lin; Shu-Lang Liao; Luke L-K Lin
Journal:  Jpn J Ophthalmol       Date:  2006 Mar-Apr       Impact factor: 2.447

2.  Comparison of efficacy of mandible and iliac bone as autogenous bone graft for orbital floor reconstruction.

Authors:  Vipul Garg; Girish B Giraddi; Swati Roy
Journal:  J Maxillofac Oral Surg       Date:  2014-07-29

3.  The use of porous polyethylene (Medpor) lower eyelid spacers in lid heightening and stabilisation.

Authors:  J Tan; J Olver; M Wright; R Maini; C Neoh; A J Dickinson
Journal:  Br J Ophthalmol       Date:  2004-09       Impact factor: 4.638

4.  Long-term follow-up of blowout fractures of the orbital floor reconstructed with a polyglactin 910/PDS implant.

Authors:  F Blake; M Blessmann; R Smeets; R Friedrich; R Schmelzle; M Heiland; W Eichhorn
Journal:  Eur J Trauma Emerg Surg       Date:  2011-02-22       Impact factor: 3.693

5.  Transnasal endoscopic removal of orbital, ethmoid sinus, and anterior skull base foreign body with mucocele formation.

Authors:  Colin D Pero; Daniel W Nuss
Journal:  Skull Base       Date:  2008-11

Review 6.  Retrospective analysis of orbital floor fractures--complications, outcome, and review of literature.

Authors:  Martin Gosau; Moritz Schöneich; Florian G Draenert; Tobias Ettl; Oliver Driemel; Torsten E Reichert
Journal:  Clin Oral Investig       Date:  2010-02-18       Impact factor: 3.573

7.  The efficacy of acrylic acid grafting and arginine-glycine-aspartic acid peptide immobilization on fibrovascular ingrowth into porous polyethylene implants in rabbits.

Authors:  Byung Woo Park; Hee Seok Yang; Se Hyun Baek; Kwideok Park; Dong Keun Han; Tae Soo Lee
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-11-22       Impact factor: 3.535

8.  Delayed onset porous polyethylene implant-related inflammation after orbital blowout fracture repair: four case reports.

Authors:  Orapan Aryasit; Danny S Ng; Alice S C Goh; Kyung In Woo; Yoon-Duck Kim
Journal:  BMC Ophthalmol       Date:  2016-07-07       Impact factor: 2.209

Review 9.  Orbital Floor Fracture.

Authors:  Hyo Seong Kim; Eui Cheol Jeong
Journal:  Arch Craniofac Surg       Date:  2016-09-23

Review 10.  Infraorbital nerve block for isolated orbital floor fractures repair: review of 135 consecutive cases.

Authors:  Giuseppe Spinelli; Davide Rocchetta; Giulia Carnevali; Domenico Valente; Marco Conti; Tommaso Agostini
Journal:  Plast Reconstr Surg Glob Open       Date:  2014-02-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.