Determination of 5-methyltetrahydrofolic acid in human serum by stable-isotope dilution high-performance liquid chromatography-mass spectrometry.

R J Pawlosky1, V P Flanagan, C M Pfeiffer.   

Abstract

The need for specific and sensitive methods for the determination of distinct serum folates is of high priority in clinical research settings. A stable-isotope liquid chromatography-mass spectrometry (LC/ESI-MS) assay was developed for the quantitative determination of the monoglutamyl form of 5-methyltetrahydrofolic acid (5-MTHFA) in human serum. Serum samples (0.5 ml) were amended with the internal standard, [5-13C5]MTHFA that had been labeled on the glutamic acid portion of the molecule and allowed to equilibrate. The analyte was trapped onto a solid-phase cartridge and then eluted with the HPLC mobile phase. Forty microliters was taken for LC/ESI-MS analysis using electrospray ionization operated in the positive ion mode. Using the standard method of addition of 5-MTHFA to serum, a linear dilution curve (y = 12.777x - 1.404; range 0.94-97 ng x ml(-1)) was constructed. The precision of the method was 5.3% (CV) based on the analysis of four sample replicates. The mass spectrum produced upon collision induced dissociation of the analyte in serum was used to confirm the identity of the 5-MTHFA. The method was applied to the analysis of a set of serum samples that contained standardized concentrations of 5-MTHFA. The determinations of 5-MTHFA in these samples using the LC/ESI-MS procedure were found to be in good agreement with other folate methods. A highly accurate and specific method for the analysis of 5-MTHFA in serum has been developed utilizing stable isotope dilution mass spectrometry. Copyright 2001 Academic Press.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11700986     DOI: 10.1006/abio.2001.5394

Source DB:  PubMed          Journal:  Anal Biochem        ISSN: 0003-2697            Impact factor:   3.365


  3 in total

1.  Accounting for an isobaric interference allows correct determination of folate vitamers in serum by isotope dilution-liquid chromatography-tandem MS.

Authors:  Zia Fazili; Christine M Pfeiffer
Journal:  J Nutr       Date:  2012-11-21       Impact factor: 4.798

2.  Quantitation of 5-methyltetraydrofolic acid in plasma for determination of folate status and clinical studies by stable isotope dilution assays.

Authors:  Lisa Striegel; Beate Brandl; Markus Kopp; Lukas Sam; Thomas Skurk; Michael Rychlik
Journal:  PLoS One       Date:  2019-02-21       Impact factor: 3.240

3.  Comprehensive Vitamer Profiling of Folate Mono- and Polyglutamates in Baker's Yeast (Saccharomyces cerevisiae) as a Function of Different Sample Preparation Procedures.

Authors:  Lena Gmelch; Daniela Wirtz; Michael Witting; Nadine Weber; Lisa Striegel; Philippe Schmitt-Kopplin; Michael Rychlik
Journal:  Metabolites       Date:  2020-07-23
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.