Organ motion detection in CT images using opposite rays in fan-beam projection systems.

N C Linney1, P H Gregson.   

Abstract

Motion artifacts have been identified as a problem in medical tomography systems. While computed tomography (CT) imaging has been getting faster, there remains a need to detect and compensate for motions in clinical follow-up of neurological patients (multiple sclerosis, tumors, stroke, etc.), in cardiac imaging, and in any area in which failing to detect a motion artifact may lead to misdiagnosis. We have developed a novel algorithm to detect motion in brain images. The algorithm deals with detecting and isolating motion in the object domain using only the information available in the sinogram domain. The new "opposite ray algorithm" (ORA) addresses the issue of motion in the interior elements of the object. The ORA combines information from projections that are opposite in space and separated in time to isolate and identify the motion. A sinogram of motion is created, integrated and reconstructed to isolate the moving component. The algorithm can be used with conventional clinical scanners employing quarter-detector offset. The significant effect of quarter-detector offset on the ORA is investigated. The effects that a finite beamwidth and noise have on the ORA are also investigated. Both the similarity index and a correlation coefficient are used to evaluate the algorithm. The algorithm is successful when applied to cases exhibiting translational and translational-rotational motion. A similarity index of 0.88 is obtained in a typical case with both translational and rotational motion. Further development is recommended in the deformation case.

Entities:  

Mesh:

Year:  2001        PMID: 11700737     DOI: 10.1109/42.963814

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  2 in total

1.  Real-time axial motion detection and correction for single photon emission computed tomography using a linear prediction filter.

Authors:  Valiallah Saba; Saeed Setayeshi; Mohammad Ghannadi-Maragheh
Journal:  Jpn J Radiol       Date:  2011-07-24       Impact factor: 2.374

2.  Correction of center of rotation and projection angle in synchrotron X-ray computed tomography.

Authors:  Chang-Chieh Cheng; Yu-Tai Ching; Pai-Hung Ko; Yeukuang Hwu
Journal:  Sci Rep       Date:  2018-06-29       Impact factor: 4.379