Literature DB >> 11700494

Intra-aneurysmal pressure after incomplete endovascular exclusion.

J C Parodi1, R Berguer, L M Ferreira, R La Mura, M L Schermerhorn.   

Abstract

PURPOSE: An endoleak results from the incomplete endovascular exclusion of an aneurysm. We developed an experimental model to analyze hemodynamic changes within the aneurysm sac in the presence of an endoleak, with and without a simulated open collateral branch.
METHODS: With a latex aneurysm model connected to a pulsatile pump, pressures were measured simultaneously within the system (systemic pressure) and the aneurysm sac (intrasac pressure). The experiments were performed without endoleak (control group) and after creating a 3.5-mm (group 1), 4.5-mm (group 2), and 6-mm (group 3) diameter orifice in the endograft, simulating an endoleak. Pressures were also registered with and without a patent aneurysm side branch.
RESULTS: In each endoleak group, the intrasac diastolic pressure (DP) and mean pressure (MP) were significantly higher than the systemic DP and MP (P =.01, P =.006, and P =.001, respectively), although the pressure curve was damped. The presence of an open side branch significantly reduced the intrasac DP and MP.
CONCLUSION: In this model, intrasac pressures were significantly higher than systemic pressures in the presence of all endoleaks, even the smallest ones. Intrasac pressures higher than systemic pressure may pose a high risk for aneurysm rupture. Although patent side branches significantly reduce these pressures, the aggressive management of an endoleak should be pursued.

Entities:  

Mesh:

Year:  2001        PMID: 11700494     DOI: 10.1067/mva.2001.119038

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  8 in total

1.  Editorial on the article entitled "the impact of intimal tear location and partial false lumen thrombosis in acute type b aortic dissection".

Authors:  Suk Jung Choo; Joon Bum Kim
Journal:  J Thorac Dis       Date:  2016-10       Impact factor: 2.895

2.  Computed Tomography Imaging Features in Acute Uncomplicated Stanford Type-B Aortic Dissection Predict Late Adverse Events.

Authors:  Anna M Sailer; Sander M J van Kuijk; Patricia J Nelemans; Anne S Chin; Aya Kino; Mark Huininga; Johanna Schmidt; Gabriel Mistelbauer; Kathrin Bäumler; Peter Chiu; Michael P Fischbein; Michael D Dake; D Craig Miller; Geert Willem H Schurink; Dominik Fleischmann
Journal:  Circ Cardiovasc Imaging       Date:  2017-04       Impact factor: 7.792

3.  Flow-independent dynamics in aneurysm (FIDA): pressure measurements following partial and complete flow impairment in experimental aneurysm model.

Authors:  Shahram Majidi; Masaki Watanabe; Saqib A Chaudhry; Adnan I Qureshi
Journal:  J Vasc Interv Neurol       Date:  2014-09

Review 4.  Secondary interventions following endovascular repair of abdominal aortic aneurysm.

Authors:  Naoki Toya; Yuji Kanaoka; Takao Ohki
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-10-22

Review 5.  Endotension: twenty years of a controversial term.

Authors:  Álvaro Torres-Blanco; Manuel Miralles-Hernández
Journal:  CVIR Endovasc       Date:  2021-06-05

6.  Influence of endoleak positions on the pressure shielding ability of stent-graft after endovascular aneurysm repair (EVAR) of abdominal aortic aneurysm (AAA).

Authors:  Jie Li; Xiaopeng Tian; Zhenze Wang; Jiang Xiong; Yubo Fan; Xiaoyan Deng; Anqiang Sun; Xiao Liu
Journal:  Biomed Eng Online       Date:  2016-12-28       Impact factor: 2.819

7.  Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study.

Authors:  Fabian Springer; Roland Schlierf; Joachim-Georg Pfeffer; Andreas H Mahnken; Uwe Schnakenberg; Thomas Schmitz-Rode
Journal:  Eur Radiol       Date:  2007-03-06       Impact factor: 7.034

8.  Is Partially Thrombosed False Lumen Really a Predictor for Adverse Events in Uncomplicated Type B Aortic Dissection: A Systematic Review and Meta-Analysis?

Authors:  Jinlin Wu; Jian Song; Xin Li; Jue Yang; Changjiang Yu; Chenyu Zhou; Tucheng Sun; Ruixin Fan
Journal:  Front Cardiovasc Med       Date:  2022-01-18
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.