Literature DB >> 11700076

Enhanced EPR sensitivity from a ferroelectric cavity insert.

Y E Nesmelov1, J T Surek, D D Thomas.   

Abstract

We report the development of a simple ferroelectric cavity insert that increases the electron paramagnetic resonance (EPR) sensitivity by an order of magnitude when a sample is placed within it. The insert is a hollow cylinder (length 4.8 mm, outside diameter 1.7 mm, inside diameter 0.6 mm) made from a single crystal of KTaO(3), which has a dielectric constant of 230 at X-band (9.5 GHz). Its outside dimensions were chosen to produce a resonant frequency in the X-band range, based on electromagnetic field modeling calculations. The insert increases the microwave magnetic field (H(1)) at the center of the insert by a factor of 7.4 when placed in an X-band TM(110) cavity. This increases the EPR signal for a small (volume 0.13 microL) unsaturated nitroxide spin label sample by a factor of 64 at constant microwave power, and by a factor of 9.8 at constant H(1). The insert does not significantly affect the cavity quality factor Q, indicating that this device simply redistributes the microwave fields within the cavity, focusing H(1) onto the sample inside the insert, thus increasing the filling factor. A similar signal enhancement is obtained in the TM(110) and TE(102) cavities, and when the insert is oriented either vertically (parallel to the microwave field) or horizontally (parallel to the DC magnetic field) in the TM(110) cavity. This order-of-magnitude sensitivity enhancement allows EPR spectroscopy to be performed in conventional high-Q cavities on small EPR samples previously only measurable in loop-gap or dielectric resonators. This is of particular importance for small samples of spin-labeled biomolecules. Copyright 2001 Academic Press.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11700076     DOI: 10.1006/jmre.2001.2415

Source DB:  PubMed          Journal:  J Magn Reson        ISSN: 1090-7807            Impact factor:   2.229


  4 in total

1.  Aqueous sample in an EPR cavity: sensitivity considerations.

Authors:  Yuri E Nesmelov; Anand Gopinath; David D Thomas
Journal:  J Magn Reson       Date:  2004-03       Impact factor: 2.229

2.  Dielectric microwave resonators in TE(011) cavities for electron paramagnetic resonance spectroscopy.

Authors:  Richard R Mett; Jason W Sidabras; Iryna S Golovina; James S Hyde
Journal:  Rev Sci Instrum       Date:  2008-09       Impact factor: 1.523

3.  EPR UNIFORM FIELD SIGNAL ENHANCEMENT BY DIELECTRIC TUBES IN CAVITIES.

Authors:  James S Hyde; Richard R Mett
Journal:  Appl Magn Reson       Date:  2017-09-18       Impact factor: 0.831

4.  Homogeneous antibody fragment conjugation by disulfide bridging introduces 'spinostics'.

Authors:  Felix F Schumacher; Vishal A Sanchania; Berend Tolner; Zoë V F Wright; Chris P Ryan; Mark E B Smith; John M Ward; Stephen Caddick; Christopher W M Kay; Gabriel Aeppli; Kerry A Chester; James R Baker
Journal:  Sci Rep       Date:  2013       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.