Literature DB >> 11698810

The role of radiographic phase-contrast imaging in the development of intracochlear electrode arrays.

J Xu1, A W Stevenson, D Gao, M Tykocinski, D Lawrence, S W Wilkins, G M Clark, E Saunders, R S Cowan.   

Abstract

OBJECTIVE: This study describes the application of a new radiographic imaging modality, phase-contrast radiography, to in vitro human temporal bone imaging and investigates its use in the development of new electrode arrays for cochlear implants.
BACKGROUND: The development of perimodiolar electrode arrays for cochlear implants requires detailed information from postoperative radiologic assessment on the position of the array in relation to the cochlear structures. Current standard radiographic techniques provide only limited details.
MATERIALS AND METHODS: Nucleus standard electrode arrays and perimodiolar Contour electrode arrays were implanted into the scala tympani of 11 human temporal bones. Both conventional and phase-contrast radiographs were taken of each temporal bone for comparative purposes.
RESULTS: Phase-contrast imaging provides better visualization of anatomic details of the inner ear and of the structure of the intracochlear electrode array, and better definition of electrode location in relation to cochlear walls.
CONCLUSION: Phase-contrast radiography offers significant improvement over conventional radiography in images of in vitro human temporal bones. It seems to be a valuable tool in the development of intracochlear electrode arrays and cochlear implant research. However, this new radiographic technique still requires certain computational and physics challenges to be addressed before its clinical use can be established.

Entities:  

Mesh:

Year:  2001        PMID: 11698810     DOI: 10.1097/00129492-200111000-00026

Source DB:  PubMed          Journal:  Otol Neurotol        ISSN: 1531-7129            Impact factor:   2.311


  3 in total

1.  Multisection CT as a valuable tool in the postoperative assessment of cochlear implant patients.

Authors:  Berit M Verbist; Johan H M Frijns; Jakob Geleijns; Mark A van Buchem
Journal:  AJNR Am J Neuroradiol       Date:  2005-02       Impact factor: 3.825

2.  An improved cochlear implant electrode array for use in experimental studies.

Authors:  Robert Shepherd; Kristien Verhoeven; Jin Xu; Frank Risi; James Fallon; Andrew Wise
Journal:  Hear Res       Date:  2011-04-22       Impact factor: 3.208

3.  Assessing the Placement of the Cochlear Slim Perimodiolar Electrode Array by Trans Impedance Matrix Analysis: A Temporal Bone Study.

Authors:  Ángel Ramos de Miguel; Diego Riol Sancho; Juan Carlos Falcón-González; Joana Pavone; Leandro Rodríguez Herrera; Silvia Borkoski Barreiro; Nadia Falcón Benitez; Ángel Ramos Macias
Journal:  J Clin Med       Date:  2022-07-06       Impact factor: 4.964

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.