Literature DB >> 11693422

Tibial implants: biomechanical and histomorphometric studies of hydroxyapatite-coated and uncoated stainless steel and titanium screws in long-term ovariectomized sheep.

M Rocca1, M Fini, G Giavaresi, N Nicoli Aldini, R Giardin.   

Abstract

This study was designed to evaluate osteointegration of HA-coated and uncoated titanium and stainless steel screws in the cortical bone of long-term (24 months) ovariectomized sheep (OVX group), in comparison with Sham-aged sheep (control group). The screws were tested biomechanically (extraction torque) and histomorphometrically (affinity index: Al) 12 weeks after their implantation in tibial diaphyses. Tibial cortical bone parameters showed significant differences between the groups, showing a reduction of the selected parameters in the OVX group. ANOVA showed significant effects for both material and ovariectomy factors on obtained extraction torque (material: F=159.26, p < 0.0005; ovariectomy: F=20.04, p < 0.0005) and Al data (material: F=8.04, p < 0.001; ovariectomy: F=7, 17, p < 0.05). In both groups the extraction torque for coated screws of both materials was significantly higher than for uncoated screws, and uncoated titanium had a better extraction torque than uncoated stainless steel. In the OVX group, the HA-coated stainless steel and titanium Al data were significantly higher than uncoated Al data. In conclusion, the biomechanical and histomorphological results obtained suggest employing HA-coated screws in the presence of osteopenic cortical bone.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11693422

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  3 in total

1.  Electron Microprobe Analysis and Tissue Reaction around Titanium Alloy Spinal Implants.

Authors:  Hee-Dong Kim; Ki-Soo Kim; Sung-Chan Ki; Yong-Soo Choi
Journal:  Asian Spine J       Date:  2007-06-30

2.  Inhibition of cathepsin K promotes osseointegration of titanium implants in ovariectomised rats.

Authors:  Chun Yi; Ke-Yi Hao; Ting Ma; Ye Lin; Xi-Yuan Ge; Yu Zhang
Journal:  Sci Rep       Date:  2017-03-17       Impact factor: 4.379

3.  The development of whole blood titanium levels after instrumented spinal fusion - is there a correlation between the number of fused segments and titanium levels?

Authors:  Ingmar Ipach; Ralf Schäfer; Falk Mittag; Carmen Leichtle; Petra Wolf; Torsten Kluba
Journal:  BMC Musculoskelet Disord       Date:  2012-08-27       Impact factor: 2.362

  3 in total