Literature DB >> 11687997

Clinical applicability of the substitution of mixed venous oxygen saturation with central venous oxygen saturation.

S Turnaoğlu1, M Tuğrul, E Camci, N Cakar, O Akinci, P Ergin.   

Abstract

OBJECTIVE: To examine the clinical applicability of substituting central venous oxygen saturation (ScvO2) for mixed venous oxygen saturation (SmvO2) in monitoring global tissue oxygenation.
DESIGN: Prospective clinical investigation.
SETTING: University hospital. PARTICIPANTS: Seventy-three adult patients.
INTERVENTIONS: Venous oxygen saturation was recorded, and oxygen saturation difference between SmvO2 and ScvO2 (DeltaSmvcv) was calculated in 2 groups of patients (group I, sepsis patients [n = 41], and group II, general anesthesia for cardiovascular surgery patients [n = 32]) during initial placement of pulmonary artery catheters.
MEASUREMENTS AND MAIN RESULTS: Patients were classified as follows: class A, patients having a DeltaSmvcv >-5%; class B, patients having a DeltaSmvcv between -5% and +5%; and class C, patients having a DeltaSmvcv >+5 %. Statistically significant differences were observed in cardiac index, oxygen delivery index, and oxygen extraction ratio between class A and B in both groups. Class C of group II showed the worst correlation between SmvO2 and ScvO2 and had significantly lower arterial carbon dioxide tension values than class A and B.
CONCLUSION: Pulmonary artery blood sampling should not be replaced with central venous blood. Hypocapnia and increased oxygen extraction ratio seem to be the major factors that worsen the relationship between ScvO2 and SmvO2. Copyright 2001 by W.B. Saunders Company

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11687997     DOI: 10.1053/jcan.2001.26534

Source DB:  PubMed          Journal:  J Cardiothorac Vasc Anesth        ISSN: 1053-0770            Impact factor:   2.628


  8 in total

1.  Mixed venous oxygen saturation cannot be estimated by central venous oxygen saturation in septic shock.

Authors:  Marjut Varpula; Sari Karlsson; Esko Ruokonen; Ville Pettilä
Journal:  Intensive Care Med       Date:  2006-07-07       Impact factor: 17.440

Review 2.  Perioperative cardiovascular monitoring of high-risk patients: a consensus of 12.

Authors:  Jean-Louis Vincent; Paolo Pelosi; Rupert Pearse; Didier Payen; Azriel Perel; Andreas Hoeft; Stefano Romagnoli; V Marco Ranieri; Carole Ichai; Patrice Forget; Giorgio Della Rocca; Andrew Rhodes
Journal:  Crit Care       Date:  2015-05-08       Impact factor: 9.097

3.  Serum Lactate Is not Correlated with Mixed or Central Venous Oxygen Saturation for Detecting Tissue Hypo Perfusion During Coronary Artery Bypass Graft Surgery: A Prospective Observational Study.

Authors:  Shahrbano Shahbazi; Saeed Khademi; Masih Shafa; Reza Joybar; Maryam Hadibarhaghtalab; Mohammad Ali Sahmeddini
Journal:  Int Cardiovasc Res J       Date:  2013-12-01

4.  The effect of epidural dexmedetomidine on oxygenation and shunt fraction in patients undergoing thoracotomy and one lung ventilation: A randomized controlled study.

Authors:  Prachi Kar; Padmaja Durga; Ramachandran Gopinath
Journal:  J Anaesthesiol Clin Pharmacol       Date:  2016 Oct-Dec

5.  The concentration of oxygen, lactate and glucose in the central veins, right heart, and pulmonary artery: a study in patients with pulmonary hypertension.

Authors:  Guillermo Gutierrez; Anthony Venbrux; Elizabeth Ignacio; Jonathan Reiner; Lakhmir Chawla; Anish Desai
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

6.  The effects of thoracic epidural analgesia on oxygenation and pulmonary shunt fraction during one-lung ventilation: an meta-analysis.

Authors:  Xiao-Qian Li; Wen-Fei Tan; Jun Wang; Bo Fang; Hong Ma
Journal:  BMC Anesthesiol       Date:  2015-11-19       Impact factor: 2.217

7.  Nebulized dexmedetomidine improves pulmonary shunt and lung mechanics during one-lung ventilation: a randomized clinical controlled trial.

Authors:  Bo Xu; Hong Gao; Dan Li; Chunxiao Hu; Jianping Yang
Journal:  PeerJ       Date:  2020-06-05       Impact factor: 2.984

8.  Effects of Iloprost on Oxygenation during One-Lung Ventilation in Patients with Low Diffusing Capacity for Carbon Monoxide: A Randomized Controlled Study.

Authors:  Kyuho Lee; Young Jun Oh; Mina Kim; Sei Han Song; Namo Kim
Journal:  J Clin Med       Date:  2022-03-11       Impact factor: 4.241

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.