Literature DB >> 11687376

Iris alteration using mechanical iris retractors.

D Tognetto1, G Agolini, G Grandi, G Ravalico.   

Abstract

A 74-year-old woman had a 3-port pars plana vitrectomy for a dropped nucleus after complicated phacoemulsification. Flexible nylon iris retractors were positioned to dilate the small pupil. The patient died of a pulmonary embolus 1 day after surgery. The eyeball was removed at autopsy, and pathology of the iris was investigated. Localized damage to the iris where the retractor hooks were positioned was noted, but no other alterations to the iris were observed. These findings may explain the recovery of pupil function that is common after surgery with mechanical iris retractors.

Entities:  

Mesh:

Year:  2001        PMID: 11687376     DOI: 10.1016/s0886-3350(01)00764-7

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351