Literature DB >> 11686281

Dose resolution optimization of polymer gel dosimeters using different monomers.

M Lepag1, P M Jayasakera, S A Bäck, C Baldock.   

Abstract

Polymer gel dosimeters of different formulations were manufactured from different monomers of acrylamide, acrylic acid, methacrylic acid, 1-vinyl-2-pyrrolidinone, 2-hydroxyethyl methacrylate and 2-hydroxyethyl acrylate. Gelatin and agarose were used as the gelling agents and N,N'-methylene-bis-acrylamide was used as a co-monomer in each polymer gel dosimeter. The T2 dependence of each dosimeter was analysed using a model of fast exchange of magnetization. The influence of the half-dose and the apparent T2 of the polymer-proton pool on the dose resolution (Dpdelta) were examined. Comparisons are made with the commonly employed R2-dose sensitivity. Differences exist suggesting that experiments reported in the literature using what were thought to be more optimal dosimeters may not actually be so. Based on Dpdelta of each formulation, conclusions are drawn on the optimal formulation required for a specific range of absorbed doses. In addition, information about the extent of polymerization of the monomers used along with some characteristics of the polymer network formed are reported. The influence of the concentration of monomers and gelling agent was subsequently evaluated using a model of fast exchange of magnetization. Based on these calculations, further improvement in Dpdelta can be expected.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11686281     DOI: 10.1088/0031-9155/46/10/310

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  A variable echo-number method for estimating R2 in MRI-based polymer gel dosimetry.

Authors:  Yoichi Watanabe; Hitoshi Kubo
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

Review 2.  Polymer gel dosimetry.

Authors:  C Baldock; Y De Deene; S Doran; G Ibbott; A Jirasek; M Lepage; K B McAuley; M Oldham; L J Schreiner
Journal:  Phys Med Biol       Date:  2010-02-11       Impact factor: 3.609

3.  Small field dose delivery evaluations using cone beam optical computed tomography-based polymer gel dosimetry.

Authors:  Timothy Olding; Oliver Holmes; Paul Dejean; Kim B McAuley; Ken Nkongchu; Giles Santyr; L John Schreiner
Journal:  J Med Phys       Date:  2011-01

4.  Improved Dose Response of N-(hydroxymethyl)acrylamide Gel Dosimeter with Calcium Chloride for Radiotherapy.

Authors:  Khalid A Rabaeh; Rawan E Al-Tarawneh; Molham M Eyadeh; Issra' M E Hammoudeh; Moneeb T M Shatnawi
Journal:  Gels       Date:  2022-01-26
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.