Literature DB >> 11686245

Laboratory and field evaluation of measurement methods for one-hour exposures to O3, PM2.5, and CO.

L T Chang1, H H Suh, J M Wolfson, K Misra, G A Allen, P J Catalano, P Koutrakis.   

Abstract

While researchers have linked acute (less than 12-hr) ambient O3, PM2.5, and CO concentrations to a variety of adverse health effects, few studies have characterized short-term exposures to these air pollutants, in part due to the lack of sensitive, accurate, and precise sampling technologies. In this paper, we present results from the laboratory and field evaluation of several new (or modified) samplers used in the "roll-around" system (RAS), which was developed to measure 1-hr O3, PM2.5, and CO exposures simultaneously. All the field evaluation data were collected during two sampling seasons: the summer of 1998 and the winter of 1999. To measure 1-hr O3 exposures, a new active O3 sampler was developed that uses two nitrite-coated filters to measure O3 concentrations. Laboratory chamber tests found that the active O3 sampler performed extremely well, with a collection efficiency of 0.96 that did not vary with temperature or relative humidity (RH). In field collocation comparisons with a reference UV photometric monitor, the active O3 sampler had an effective collection efficiency ranging between 0.92 and 0.96 and a precision for 1-hr measurements ranging between 4 and 6 parts per billion (ppb). The limits of detection (LOD) of this method were 9 ppb-hr for the chamber tests and approximtely 16 ppb-hr for the field comparison tests. PM2.5 and CO concentrations were measured using modified continuous monitors--the DustTrak and the Langan, respectively. A size-selective inlet and a Nafion dryer were placed upstream of the DustTrak inlet to remove particles with aerodynamic diameters greater than 2.5 microm and to dry particles prior to the measurements, respectively. During the field validation tests, the DustTrak consistently reported higher PM2.5 concentrations than those obtained by the collocated 12-hr PM2.5 PEM samples, by approximately a factor of 2. After the DustTrak response was corrected (correction factor of 2.07 in the summer and 2.02 in the winter), measurements obtained using these methods agreed well with R2 values of 0.87 in the summer and 0.81 in the winter. The results showed that the DustTrak can be used along with integrated measurements to measure the temporal and spatial variation in PM2.5 exposures. Finally, during the field validation tests, CO concentrations measured using the Langan were strongly correlated with those obtained using the reference method when the CO levels were above the LOD of the instrument [approximately 1 part per million (ppm)].

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11686245

Source DB:  PubMed          Journal:  J Air Waste Manag Assoc        ISSN: 1096-2247            Impact factor:   2.235


  6 in total

1.  Comparing gravimetric and real-time sampling of PM(2.5) concentrations inside truck cabins.

Authors:  Ying Zhu; Thomas J Smith; Mary E Davis; Jonathan I Levy; Robert Herrick; Hongyu Jiang
Journal:  J Occup Environ Hyg       Date:  2011-11       Impact factor: 2.155

2.  Association between fine particulate matter and oxidative DNA damage may be modified in individuals with hypertension.

Authors:  Jee Young Kim; Lacey A Prouty; Shona C Fang; Ema G Rodrigues; Shannon R Magari; Geoffrey A Modest; David C Christiani
Journal:  J Occup Environ Med       Date:  2009-10       Impact factor: 2.162

3.  Comparison of real-time instruments and gravimetric method when measuring particulate matter in a residential building.

Authors:  Zuocheng Wang; Leonardo Calderón; Allison P Patton; MaryAnn Sorensen Allacci; Jennifer Senick; Richard Wener; Clinton J Andrews; Gediminas Mainelis
Journal:  J Air Waste Manag Assoc       Date:  2016-11       Impact factor: 2.235

4.  Modeling spatial patterns of traffic-related air pollutants in complex urban terrain.

Authors:  Leonard M Zwack; Christopher J Paciorek; John D Spengler; Jonathan I Levy
Journal:  Environ Health Perspect       Date:  2011-01-24       Impact factor: 9.031

5.  The air quality impacts of road closures associated with the 2004 Democratic National Convention in Boston.

Authors:  Jonathan I Levy; Lisa K Baxter; Jane E Clougherty
Journal:  Environ Health       Date:  2006-05-26       Impact factor: 5.984

6.  Diabetes, obesity, and hypertension may enhance associations between air pollution and markers of systemic inflammation.

Authors:  Sara D Dubowsky; Helen Suh; Joel Schwartz; Brent A Coull; Diane R Gold
Journal:  Environ Health Perspect       Date:  2006-07       Impact factor: 9.031

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.