Comparison of beclomethasone dipropionate delivery by easyhaler dry powder inhaler and pMDI plus large volume spacer.

S P Newman1, G R Pitcairn, D A Adkin, M T Vidgren, M Silvasti.   

Abstract

Dry powder inhalers (DPIs) provide a means of delivering inhaled asthma drugs without the use of propellants. Easyhaler is a multidose DPI, delivering 200 doses of beclomethasone dipropionate (BDP), 200 microg/dose. A gamma scintigraphic study has been carried out in 10 healthy volunteers to compare the deposition of BDP from Easyhaler with that from a pressurized metered dose inhaler (pMDI) coupled to a Volumatic spacer device delivering 250 microg BDP per dose. The spacer was used without any pretreatment to reduce static charge on the spacer walls. The study was conducted according to an open, randomized, crossover design. The volunteers inhaled the study drug using optimal inhalation technique for both devices. Lung deposition of 99mTc-labeled BDP averaged 18.9% (SD 9.5%) of the metered dose for Easyhaler, and 11.2% (SD 5.3%) for pMDI plus spacer (p < 0.05); when the data were expressed as mass of BDP deposited in the lungs, the difference in lung deposition just failed to reach statistical significance (Easyhaler 37.8 microg; pMDI plus spacer 28.0 microg). Oropharyngeal deposition was significantly reduced by use of the spacer. The results of this study show that Easyhaler delivers drug more efficiently to the lungs than pMDI plus Volumatic spacer when no measures are taken to eliminate static charge on the spacer walls.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11681653     DOI: 10.1089/08942680152484144

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  7 in total

Review 1.  Deposition and effects of inhaled corticosteroids.

Authors:  Stephen P Newman
Journal:  Clin Pharmacokinet       Date:  2003       Impact factor: 6.447

Review 2.  Mechanisms of pharmaceutical aerosol deposition in the respiratory tract.

Authors:  Yung Sung Cheng
Journal:  AAPS PharmSciTech       Date:  2014-02-22       Impact factor: 3.246

3.  Effect of shape of sodium salicylate particles on physical property and in vitro aerosol performance of granules prepared by pressure swing granulation method.

Authors:  Masayuki Watanabe; Tetsuya Ozeki; Tomoko Shibata; Hayato Murakoshi; Yuuki Takashima; Hiroshi Yuasa; Hiroaki Okada
Journal:  AAPS PharmSciTech       Date:  2003-12-16       Impact factor: 3.246

Review 4.  Lung Deposition and Inspiratory Flow Rate in Patients with Chronic Obstructive Pulmonary Disease Using Different Inhalation Devices: A Systematic Literature Review and Expert Opinion.

Authors:  Adolfo Baloira; Araceli Abad; Antonia Fuster; Juan Luis García Rivero; Patricia García-Sidro; Eduardo Márquez-Martín; Marta Palop; Néstor Soler; J L Velasco; Fernando González-Torralba
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2021-04-19

5.  FIDEPOC: Consensus on Inspiratory Flow and Lung Deposition as Key Decision Factors in COPD Inhaled Therapy.

Authors:  Fernando González-Torralba; Adolfo Baloira; Araceli Abad; Antonia Fuster; Juan Luis García-Rivero; Patricia García-Sidro; Eduardo Márquez-Martín; Marta Palop; Néstor Soler; José Luis Velasco
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2022-05-04

6.  Inhaler competence and patient satisfaction with Easyhaler®: results of two real-life multicentre studies in asthma and COPD.

Authors:  Gabriella Gálffy; Györgyi Mezei; Gyula Németh; Lilla Tamási; Veronika Müller; Olof Selroos; Marta Orosz
Journal:  Drugs R D       Date:  2013-09

7.  Characteristics of reversible and nonreversible COPD and asthma and COPD overlap syndrome patients: an analysis of salbutamol Easyhaler data.

Authors:  Veronika Müller; Gabriella Gálffy; Márta Orosz; Zsuzsanna Kováts; Balázs Odler; Olof Selroos; Lilla Tamási
Journal:  Int J Chron Obstruct Pulmon Dis       Date:  2016-01-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.