Literature DB >> 11679834

Computer navigation of parapedicular screw fixation in the thoracic spine: a cadaver study.

R Kothe1, J Matthias Strauss, G Deuretzbacher, T Hemmi, M Lorenzen, L Wiesner.   

Abstract

STUDY
DESIGN: An in vitro study to investigate the advantages of computer assistance for the purpose of parapedicular screw fixation in the upper and middle thoracic spine.
OBJECTIVES: To evaluate the feasibility and application accuracy of parapedicuar screw insertion with the assistance of an optoelectronic navigation system. SUMMARY OF BACKGROUND DATA: Because of anatomic limitations, thoracic pedicle screw insertion in the upper and middle thoracic spine remains a matter of controversy. The technique of parapedicular screw insertion has been described as an alternative, although the exact screw position is difficult to control. With the assistance of computer navigation for the screw placement, it might become possible to overcome these challenges.
METHODS: Four human specimens were harvested for this study; 6-mm screws were inserted from T2 to T8 with the assistance of a CT-based optoelectronic navigation system. During surgery virtual images of the screw position were documented and compared with postoperative contact radiographs to determine the application accuracy. The following measurements were obtained: axial and sagittal screw angles as well as the screw distances to the anterior vertebral cortex and the medial pedicle wall.
RESULTS: All 54 screws were inserted in a parapedicular technique without violation of the medial pedicle wall or the anterior or lateral vertebral cortex. The mean +/- standard deviation difference between the virtual images and the radiographs was 1.0 +/- 0.94 mm for the distance to the medial pedicle wall and 1.9 +/- 1.44 mm for the distance to the anterior cortex. The angular measurements showed a difference of 1.6 +/- 1.1 degrees for the transverse screw angle and 2.1 +/- 1.6 degrees for the sagittal screw orientation.
CONCLUSION: With the assistance of computer navigation it is possible to achieve a safe and reliable parapedicular screw insertion in the upper and middle thoracic spine in vitro. The application accuracy varies for the linear and angular measurements and is higher in the axial than in the sagittal plane. It is important for the surgeon to understand these limitations when using computer navigation in spinal surgery.

Entities:  

Mesh:

Year:  2001        PMID: 11679834     DOI: 10.1097/00007632-200111010-00019

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  8 in total

1.  [Intraoperative three-dimensional navigation for pedicle screw placement].

Authors:  P A Grützner; T Beutler; K Wendl; J von Recum; A Wentzensen; L-P Nolte
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

2.  An evaluation of image-guided technologies in the placement of anterior thoracic vertebral body screws in spinal trauma: a cadaver study.

Authors:  Alexander R Vaccaro; Philip S Yuan; Harvey E Smith; Jonathon Hott; Rick Sasso; Stephen Papadopoulos
Journal:  J Spinal Cord Med       Date:  2005       Impact factor: 1.985

3.  Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance.

Authors:  Eric W Nottmeier; Andrew B Foy
Journal:  Eur Spine J       Date:  2007-11-22       Impact factor: 3.134

4.  Pedicle screw insertion: computed tomography versus fluoroscopic image guidance.

Authors:  Tsai-Sheng Fu; Chak-Bor Wong; Tsung-Ting Tsai; Yen-Chiu Liang; Lih-Huei Chen; Wen-Jer Chen
Journal:  Int Orthop       Date:  2007-04-05       Impact factor: 3.075

Review 5.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

6.  A novel computer-assisted drill guide template for placement of C2 laminar screws.

Authors:  Sheng Lu; Yong Q Xu; Yuan Z Zhang; Le Xie; Hai Guo; Dong P Li
Journal:  Eur Spine J       Date:  2009-06-11       Impact factor: 3.134

Review 7.  Differences between Manufacturers of Computed Tomography-Based Computer-Assisted Surgery Systems Do Exist: A Systematic Literature Review.

Authors:  Anas Nooh; Joushua Lubov; Ahmed Aoude; Sultan Aldebeyan; Peter Jarzem; Jean Ouellet; Michael H Weber
Journal:  Global Spine J       Date:  2017-02-01

Review 8.  Biomechanics and clinical outcome after posterior stabilization of mid-thoracic vertebral body fractures: a systematic literature review.

Authors:  Ulrich J Spiegl; Georg Osterhoff; Philipp Bula; Frank Hartmann; Max J Scheyerer; Klaus J Schnake; Bernhard W Ullrich
Journal:  Eur J Trauma Emerg Surg       Date:  2020-12-02       Impact factor: 3.693