Literature DB >> 11679298

A novel measuring system for the determination of paramagnetic particle labels for use in magneto-immunoassays.

J Richardson1, A Hill, R Luxton, P Hawkins.   

Abstract

Coated micrometer-sized paramagnetic particles (PMPs) are readily available and widely used in immunoassays, mainly for separation and as a solid phase. We have described in a separate paper a model sandwich assay in which approximately 1 x 10(5) to 1 x 10(6) PMPs (2.8 microm diameter) are immobilised on a plastic strip at the end of the assay. In this paper, we describe the design of an instrument that is capable of determining the number of PMPs on the plastic strip. The paper also describes a method of making standard plastic strips with known numbers of PMPs on them. A strip, when placed in a coil of wire in parallel with a capacitor, causes the resonant frequency of the coil to decrease because of the presence of the PMPs. The decrease in frequency relates directly to the number of PMPs on the strip. A circuit based on a voltage-controlled oscillator and a phase-locked loop is used to accurately measure the resonant frequency of the coil. The instrument is capable of detecting at least 1 x 10(5) PMPs immobilised on a plastic strip and has a linear response (r=0.99) for up to at least 3.33 x 10(6) PMPs. In terms of the iron content of the PMPs, the detection limit is approximately equal to 1.2 microg Fe in the paramagnetic particles and the sensitivity is approximately equal to 3 Hz per microg of Fe. The instrument is small and compact and together with a suitable magneto-immunoassay will have many applications, including near-patient monitoring.

Entities:  

Mesh:

Year:  2001        PMID: 11679298     DOI: 10.1016/s0956-5663(01)00241-x

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  Immunological methods for detection and identification of infectious disease and biological warfare agents.

Authors:  Anne Harwood Peruski; Leonard F Peruski
Journal:  Clin Diagn Lab Immunol       Date:  2003-07

2.  An inexpensive, fast and sensitive quantitative lateral flow magneto-immunoassay for total prostate specific antigen.

Authors:  Jacqueline M Barnett; Patrick Wraith; Janice Kiely; Raj Persad; Katrina Hurley; Peter Hawkins; Richard Luxton
Journal:  Biosensors (Basel)       Date:  2014-07-08

Review 3.  Magneto-Impedance Biosensor Sensitivity: Effect and Enhancement.

Authors:  Abkar Sayad; Efstratios Skafidas; Patrick Kwan
Journal:  Sensors (Basel)       Date:  2020-09-12       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.