Literature DB >> 11679021

Is home peak expiratory flow monitoring effective for controlling asthma symptoms?

A M McGrath1, D M Gardner, J McCormack.   

Abstract

A case in which a home peak expiratory flow (PEF) monitoring device was recommended led us to review the evidence examining this intervention. The clinical question to be answered was: should these devices be consistently recommended to all patients with asthma? A comprehensive search revealed eight randomized controlled trials, one review and one consensus report. Four trials provided all subjects with asthma education and compared patient-specific action plans based on symptoms to those based on PEF readings. Four trials compared usual asthma care to peak flow monitoring (PFM) and varied in both their content and intensity of asthma education. Six out of eight studies showed improvement in some selected markers of asthma morbidity with home PFM-based action plans. Improvements were also observed in patients using a symptom-based action plan. These studies did not demonstrate any obvious advantage of PFM compared with symptom-based monitoring but did suggest that a monitoring plan with predetermined actions based on PEF measurements or symptoms can lead to improved asthma control. Although not specifically studied, PFM may be more appropriate and effective for patients who have difficulty identifying worsening of asthma control through symptom monitoring.

Entities:  

Mesh:

Year:  2001        PMID: 11679021     DOI: 10.1046/j.1365-2710.2001.00374.x

Source DB:  PubMed          Journal:  J Clin Pharm Ther        ISSN: 0269-4727            Impact factor:   2.512


  4 in total

1.  Are peak flow meters readily available in community pharmacies?

Authors:  Hoan Linh Banh; Elaheh Ahmadi; Andrew Cave
Journal:  Can Pharm J (Ott)       Date:  2016-05-27

2.  Quantitative and qualitative usage data of an Internet-based asthma monitoring tool.

Authors:  Jacob Anhøj; Lene Nielsen
Journal:  J Med Internet Res       Date:  2004-09-03       Impact factor: 5.428

3.  Comparison between Emergency Severity Index plus peak flow meter and Emergency Severity Index in the dyspneic patients with chronic obstructive pulmonary disease: A randomized clinical trial.

Authors:  Mahin Hamechizfahm Roudi; Javad Malekzadeh; Mohsen Ebrahimi; Amir Mirhaghi; MohammadTaghi Shakeri
Journal:  Turk J Emerg Med       Date:  2019-04-17

4.  Implementing asthma management guidelines in public primary care clinics in Malaysia.

Authors:  Ai Theng Cheong; Ping Yein Lee; Sazlina Shariff-Ghazali; Hani Salim; Norita Hussein; Rizawati Ramli; Hilary Pinnock; Su May Liew; Nik Sherina Hanafi; Ahmad Ihsan Abu Bakar; Azainorsuzila Mohd Ahad; Yong Kek Pang; Karuthan Chinna; Ee Ming Khoo
Journal:  NPJ Prim Care Respir Med       Date:  2021-11-29       Impact factor: 2.871