Literature DB >> 1167672

The radioactive microsphere method for the assessment of regional myocardial blood flow after coronary artery occlusion. Inaccuracies due to variations in the diameter distribution of the spheres.

R S Reneman, A H Jageneau, W van Gerven, J Dony, P Beirnaert.   

Abstract

In this study, we have tried to determine the magnitude of the inaccuracy of the radioactive microsphere method - due to variations in the diameter distribution of the spheres - for measuring regional myocardial blood flow after coronary artery occlusion. In 5 mongrel dogs, three types of 15 mum microspheres, labelled with 125I, 141Ce or 85Sr, were injected simultaneously after the descending branch of the left coronary artery had been ligated. Myocardial samples wert taken from the left ventricle and divided into four groups according to the number of spheres per sample. The radioactivity of the various isotopes per gram tissue was expressed as percentage of their activity per milliliter of the reference sample. The diameter distribution of microspheres, labelled with each of the isotopes, was determined light-microscopically in suspensions belonging to three different batches. The relative error, as determined from the difference in relative radioactivity of the various types of microspheres in the tissue samples, was higher than the theoretical error for each of the number of spheres per sample. It is very likely that this discrepancy is caused by the differences in diameter distribution of the various types of microspheres, resulting in non-random error. The smaller spheres tended to go to low flow areas and the larger ones to high flow areas. Because of the non-randomness, the error due to diameter variations in the spheres can be diminished by randomizing the order of injection of the various isotopes. The present study indicates that the relatively high degree of accuracy of the microsphere method for the determination of blood flow to large parts of the myocardium with an unimpeded coronary circulation, as was described in literature, cannot be extrapolated to the determination of regional myocardial blood flow after coronary artery occlusion, when the combination of small tissue samples, variations in the diameter distribution of the spheres and an unevenly distributed myocardial blood flow unfavourably affect the accuracy of the method.

Entities:  

Mesh:

Substances:

Year:  1975        PMID: 1167672     DOI: 10.1007/bf00587030

Source DB:  PubMed          Journal:  Pflugers Arch        ISSN: 0031-6768            Impact factor:   3.657


  14 in total

1.  THE DETERMINANTS OF THE RATE OF CHANGE OF THE LEFT VENTRICULAR PRESSURE (DP/DT).

Authors:  W K SCHAPER; P LEWI; A H JAGENEAU
Journal:  Arch Kreislaufforsch       Date:  1965-03

2.  Total and regional coronary blood flow during acute coronary occlusion in anaesthetized and conscious dogs.

Authors:  R J Domenech
Journal:  Cardiovasc Res       Date:  1974-05       Impact factor: 10.787

3.  Myocardial steal produced by coronary vasocilation in chronic coronary artery occlusion.

Authors:  W Schaper; P Lewi; W Flameng; L Gijpen
Journal:  Basic Res Cardiol       Date:  1973 Jan-Feb       Impact factor: 17.165

4.  Mapping of left ventricular blood flow with radioactive microspheres in experimental coronary artery occlusion.

Authors:  L C Becker; R Ferreira; M Thomas
Journal:  Cardiovasc Res       Date:  1973-05       Impact factor: 10.787

5.  Multiple experimental coronary occlusion without infarction. Effects of heart rate and vasodilation.

Authors:  W Flameng; W Schaper; P Lewi
Journal:  Am Heart J       Date:  1973-06       Impact factor: 4.749

6.  The circulation of the fetus in utero. Methods for studying distribution of blood flow, cardiac output and organ blood flow.

Authors:  A M Rudolph; M A Heymann
Journal:  Circ Res       Date:  1967-08       Impact factor: 17.367

7.  Some sources of error in measuring regional blood flow with radioactive microspheres.

Authors:  G D Buckberg; J C Luck; D B Payne; J I Hoffman; J P Archie; D E Fixler
Journal:  J Appl Physiol       Date:  1971-10       Impact factor: 3.531

8.  Total and regional coronary blood flow measured by radioactive microspheres in conscious and anesthetized dogs.

Authors:  R J Domenech; J I Hoffman; M I Noble; K B Saunders; J R Henson; S Subijanto
Journal:  Circ Res       Date:  1969-11       Impact factor: 17.367

9.  Nonuniform distribution of microspheres in blood flowing through a medium-size artery.

Authors:  R H Phibbs; L Dong
Journal:  Can J Physiol Pharmacol       Date:  1970-06       Impact factor: 2.273

10.  Validity studies of the radioactive microsphere method for the study of the distribution of cardiac output, orn blood flow, and resistance in the conscious rhesus monkey.

Authors:  B I Hoffbrand; R P Forsyth
Journal:  Cardiovasc Res       Date:  1969-10       Impact factor: 10.787

View more
  6 in total

Review 1.  Blood flow distributions by microsphere deposition methods.

Authors:  F W Prinzen; J B Bassingthwaighte
Journal:  Cardiovasc Res       Date:  2000-01-01       Impact factor: 10.787

Review 2.  Glossary: methods for the measurement of coronary blood flow and myocardial perfusion.

Authors:  S G Sakka; D R Wallbridge; G Heusch
Journal:  Basic Res Cardiol       Date:  1996 Mar-Apr       Impact factor: 17.165

3.  Distribution of microspheres of 15 +/- 5 micrometer diameter in dog kidneys.

Authors:  G Ruedas
Journal:  Experientia       Date:  1979-05-15

4.  Transmural perfusion gradients distal to various degrees of coronary artery stenosis during resting flow or at maximal vasodilation.

Authors:  D C Warltier; H F Hardman; G J Gross
Journal:  Basic Res Cardiol       Date:  1979 Sep-Oct       Impact factor: 17.165

5.  Transmural differences in myocardial blood flow and in coronary dilatory capacity in hemodiluted conscious dogs.

Authors:  J Holtz; E Bassenge; W von Restoriff; E Mayer
Journal:  Basic Res Cardiol       Date:  1976 Jan-Feb       Impact factor: 17.165

6.  Recovery of hypertrophied rat hearts after global ischemia and reperfusion at different perfusion pressures.

Authors:  L H Snoeckx; G J van der Vusse; F H van der Veen; W A Coumans; R S Reneman
Journal:  Pflugers Arch       Date:  1989-01       Impact factor: 3.657

  6 in total