Quantitative analysis of PC MRI velocity maps: pulsatile flow in cylindrical vessels.

M B Robertson1, U Köhler, P R Hoskins, I Marshall.   

Abstract

The accuracy of MR phase contrast (PC) velocity mapping, and the subsequent derivation of wall shear stress (WSS) values, has been quantitatively assessed. Using a retrospectively gated PC gradient-echo technique, the temporal-spatial velocity fields were measured for pulsatile flow in a rigid cylindrical vessel. The experimental data were compared with values derived from the Womersley solution of the Navier-Stokes equations. For a sinusoidal waveform, the overall root-mean-square (rms) difference between the measured and analytical velocities corresponded to 13% of the peak fluid velocity. The WSS derived from the data displayed a 14% rms difference with the analytical model. As an example of a more complicated flow, a triangular saw-tooth waveform was deconstructed into its Fourier components. Velocity maps and the WSS were calculated by the superposition of the individual solutions, weighted by the Fourier series coefficient, for each harmonic. The velocity and experimentally derived WSS agreed with the analytical results (4% and 12% rms difference, respectively). Evaluation of the analytical models allowed an estimate of the inherent accuracy in the measurement of velocity maps and WSS values.

Mesh:

Year:  2001        PMID: 11672627     DOI: 10.1016/s0730-725x(01)00376-9

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  4 in total

1.  Integrated physiological flow simulator and pulse sequence monitoring system for MRI.

Authors:  Pauline Wong; Martin J Graves; David J Lomas
Journal:  Med Biol Eng Comput       Date:  2008-02-22       Impact factor: 2.602

2.  Comparing velocity and fluid shear stress in a stenotic phantom with steady flow: phase-contrast MRI, particle image velocimetry and computational fluid dynamics.

Authors:  Iman Khodarahmi
Journal:  MAGMA       Date:  2014-12-12       Impact factor: 2.310

3.  Accuracy and reproducibility of phase-contrast MR imaging measurements for CSF flow.

Authors:  Andrew L Wentland; O Wieben; F R Korosec; V M Haughton
Journal:  AJNR Am J Neuroradiol       Date:  2010-03-04       Impact factor: 3.825

4.  Screening for subclinical atherosclerosis by noninvasive methods in asymptomatic patients with risk factors.

Authors:  Xavier Castellon; Vera Bogdanova
Journal:  Clin Interv Aging       Date:  2013-05-28       Impact factor: 4.458

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.