Literature DB >> 11669534

Sweeping on a microchip: concentration profiles of the focused zone in micellar electrokinetic chromatography.

Y Sera1, N Matsubara, K Otsuka, S Terabe.   

Abstract

On-line sample concentration by sweeping was investigated in microchip micellar electrokinetic chromatography (MEKC), By changing the distance between the injection cross and the detection points, the profile of the concentration process and the diffusion process in sweeping was elucidated. Rhodamine B injected for 4 s was best concentrated by sweeping at 9.4 mm from the injection cross and the enhancement factor was 450. At the longer distance from this point the peak of Rhodamine B was broadened and diluted by diffusion. The diffusion constant of Rhodamine B calculated from the experiment was 5.7 x 10(-6) cm2s(-1). The mixture of rhodamine B, sulforhodamine B, and cresyl fast violet was concentrated by sweeping and separated by MEKC at the same time.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11669534     DOI: 10.1002/1522-2683(200109)22:16<3509::AID-ELPS3509>3.0.CO;2-Z

Source DB:  PubMed          Journal:  Electrophoresis        ISSN: 0173-0835            Impact factor:   3.535


  7 in total

1.  Study of injection bias in a simple hydrodynamic injection in microchip CE.

Authors:  Maojun Gong; Kenneth R Wehmeyer; Apryll M Stalcup; Patrick A Limbach; William R Heineman
Journal:  Electrophoresis       Date:  2007-05       Impact factor: 3.535

2.  On-line sample preconcentration using field-amplified stacking injection in microchip capillary electrophoresis.

Authors:  Maojun Gong; Kenneth R Wehmeyer; Patrick A Limbach; Francisco Arias; William R Heineman
Journal:  Anal Chem       Date:  2006-06-01       Impact factor: 6.986

3.  High yield sample preconcentration using a highly ion-conductive charge-selective polymer.

Authors:  Honggu Chun; Taek Dong Chung; J Michael Ramsey
Journal:  Anal Chem       Date:  2010-07-15       Impact factor: 6.986

4.  Flow manipulation for sweeping with a cationic surfactant in microchip capillary electrophoresis.

Authors:  Maojun Gong; Kenneth R Wehmeyer; Patrick A Limbach; William R Heineman
Journal:  J Chromatogr A       Date:  2007-08-21       Impact factor: 4.759

5.  Combination of on-chip field amplification and bovine serum albumin sweeping for ultrasensitive detection of green fluorescent protein.

Authors:  Qiong Pan; Meiping Zhao; Shaorong Liu
Journal:  Anal Chem       Date:  2009-07-01       Impact factor: 6.986

6.  Improving MCE with electrochemical detection using a bubble cell and sample stacking techniques.

Authors:  Qian Guan; Charles S Henry
Journal:  Electrophoresis       Date:  2009-10       Impact factor: 3.535

Review 7.  Clinical analysis by microchip capillary electrophoresis.

Authors:  Sam F Y Li; Larry J Kricka
Journal:  Clin Chem       Date:  2005-11-18       Impact factor: 8.327

  7 in total