Literature DB >> 11669383

Comparison of filter bag, cyclonic, and wet dust collection methods in vacuum cleaners.

S Trakumas1, K Willeke, T Reponen, S A Grinshpun, W Friedman.   

Abstract

In this study, methods were developed for comparative evaluation of three primary dust collection methods employed in vacuum cleaners: filter bag, cyclonic, and wet primary dust collection. The dry collectors were evaluated with KCl test aerosols that are commonly used in filter testing. However, these aerosols cannot be used for evaluating wet collectors due to their hygroscopicity. Therefore, the wet collectors were evaluated with nonhygroscopic test particles. Both types of test aerosol indicated similar collection efficiencies in tests with dry collectors. The data show that high initial collection efficiency can be achieved by any one of the three dust collection methods: up to 50% for 0.35 microm particles, and close to 100% for 1.0 microm and larger particles. The degree of dependence of the initial collection efficiency on airflow rate was strongly related to the type and manufacturing of the primary dust collector. Collection efficiency decreased most with decreasing flow rate for the tested wet collectors. The tested cyclonic and wet collectors showed high reentrainment of already collected dust particles. After the filter bag collectors had been loaded with test dust, they also reemitted particles. The degree of reentrainment from filter bags depends on the particulate load and the type of filter material used. Thus, the overall particle emissions performance of a vacuum cleaner depends not only on the dust collection efficiency of the primary collector and other filtration elements employed, but also on the degree of reentrainment of already collected particles.

Mesh:

Substances:

Year:  2001        PMID: 11669383     DOI: 10.1080/15298660108984656

Source DB:  PubMed          Journal:  AIHAJ        ISSN: 1529-8663


  2 in total

1.  Microbial contents of vacuum cleaner bag dust and emitted bioaerosols and their implications for human exposure indoors.

Authors:  Marc Veillette; Luke D Knibbs; Ariane Pelletier; Remi Charlebois; Pascale Blais Lecours; Congrong He; Lidia Morawska; Caroline Duchaine
Journal:  Appl Environ Microbiol       Date:  2013-08-09       Impact factor: 4.792

2.  Manta rays feed using ricochet separation, a novel nonclogging filtration mechanism.

Authors:  Raj V Divi; James A Strother; E W Misty Paig-Tran
Journal:  Sci Adv       Date:  2018-09-26       Impact factor: 14.136

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.