Complications of lumbar drainage after thoracoabdominal aortic aneurysm repair.

K D Weaver1, D B Wiseman, M Farber, M G Ewend, W Marston, B A Keagy.   

Abstract

OBJECTIVES: Paraplegia remains a frequent complication of thoracoabdominal aortic aneurysm (TAAA) repair. Many adjunct therapies have been developed to address this complication. Lumbar drainage is frequently used in an attempt to decrease intrathecal pressure and improve intramedullary perfusion pressure. The effectiveness of this therapy is unclear, and the complications of lumbar drainage used for this indication are unknown. We present a case of intraspinal hematoma with significant neurologic deficit after TAAA repair and review the associated complications of lumbar drains placed for TAAA.
METHODS: The charts of all patients undergoing operations for TAAA repair were reviewed. Patients who underwent perioperative placement of a lumbar drain were included regardless of aneurysm type or etiology. Demographics, Crawford grade, and perioperative parameters and complications were reviewed.
RESULTS: Sixty-five patients underwent TAAA repair with 62 (95%) receiving a preoperative lumbar drain. There were two (3.2%) intraspinal hemorrhagic complications, including one patient with a poor neurologic outcome. No infections or other complications directly related to drainage were identified. Multivariate logistic regression analysis failed to demonstrate a significant association between lumbar drain complications and perioperative and intraoperative parameters such as blood loss or hypotension, level of drain placement, and Crawford grade.
CONCLUSIONS: Lumbar drainage is a frequent adjunct to TAAA repair. However, placement of the drain itself can be associated with significant complications whose aggravating factors may be unidentifiable. Complications resulting from lumbar drainage should be considered in any patient who has postoperative lower extremity neurologic deficits.

Entities:  

Mesh:

Year:  2001        PMID: 11668315     DOI: 10.1067/mva.2001.117334

Source DB:  PubMed          Journal:  J Vasc Surg        ISSN: 0741-5214            Impact factor:   4.268


  13 in total

1.  Effects of preemptive cerebrospinal fluid drainage on spinal cord protection during thoracic endovascular aortic repair.

Authors:  Seungjun Song; Suk-Won Song; Tae Hoon Kim; Kwang-Hun Lee; Kyung-Jong Yoo
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

2.  Post-dural puncture headaches following spinal drain placement during thoracoabdominal aortic aneurysm repair: incidence, associated risk factors, and treatment.

Authors:  Sean P Riley; Melanie J Donnelly; Didi Khatib; Christopher Warren; Kristopher M Schroeder
Journal:  J Anesth       Date:  2015-03-05       Impact factor: 2.078

Review 3.  Is cerebrospinal fluid drainage of benefit to neuroprotection in patients undergoing surgery on the descending thoracic aorta or thoracoabdominal aorta?

Authors:  Haris Bilal; Bridie O'Neill; Sarah Mahmood; Paul Waterworth
Journal:  Interact Cardiovasc Thorac Surg       Date:  2012-07-03

Review 4.  Significance of spinal cord perfusion pressure following spinal cord injury: A systematic scoping review.

Authors:  Cameron M Gee; Brian K Kwon
Journal:  J Clin Orthop Trauma       Date:  2022-09-11

5.  Temporary Lumbar Subcutaneous Cerebrospinal Fluid Shunt Placement in Pediatric Patient: A Technical Note.

Authors:  Adnan I Qureshi; WeiGang Xiao
Journal:  J Vasc Interv Neurol       Date:  2016-01

6.  Lumbar Catheter Placement Using Paramedian Approach Under Fluoroscopic Guidance.

Authors:  Adnan I Qureshi; Asif A Khan; Ahmed A Malik; Mohammad Rauf Afzal; Nabeel A Herial; Mushtaq H Qureshi; M Fareed K Suri
Journal:  J Vasc Interv Neurol       Date:  2016-01

7.  Bloody cerebrospinal fluid during replacement of descending thoracic aorta -A case report-.

Authors:  Yuseon Cheong; Jiyeon Sim; Incheol Choi
Journal:  Korean J Anesthesiol       Date:  2010-12-31

8.  Meningeal haemorrhage secondary to cerebrospinal fluid drainage during thoracic endovascular aortic repair.

Authors:  Jennifer Mancio; Gustavo Pires-Morais; Nuno Bettencourt; Marco Oliveira; Lino Santos; Bruno Melica; Alberto Rodrigues; José Pedro Braga; Vasco Gama Ribeiro
Journal:  Oxf Med Case Reports       Date:  2014-06-20

Review 9.  S100 and S100β: biomarkers of cerebral damage in cardiac surgery with or without the use of cardiopulmonary bypass.

Authors:  Shi-Min Yuan
Journal:  Rev Bras Cir Cardiovasc       Date:  2014 Oct-Dec

10.  Pneumocephalus in thoracoabdominal aortic aneurysm repair after lumbar drain removal and blood patch.

Authors:  Jack Bontekoe; Kyla Bennett
Journal:  J Vasc Surg Cases Innov Tech       Date:  2021-05-05
View more