PURPOSE: To evaluate the diagnostic value of a combined method, i.e. ergometer cycling with continuous bilateral transcranial Doppler monitoring (TCD) to detect cerebral hemodynamic abnormalities in recently diagnosed hypertensive patients. METHODS: 30 neurologically symptom-free, nontreated patients with essential hypertension and 30 age- and sex-matched controls were studied. Carotid ultrasound, resting ECG and blood parameters were investigated. Cycling ergometry was performed according to the WHO protocol. Blood pressure, heart rate, end-tidal CO2 (etCO2) and bilateral middle cerebral artery (MCA) blood flow velocity (MV) were monitored. RESULTS: At rest, MV in the MCA did not differ significantly between controls and hypertensive subjects. MV continuously increased in controls until the end of loading whereas a plateau was reached at 4 min in hypertensive subjects. During 6 min of cycling, the time course of absolute values of MV in the MCA and that of the changes in the ratio of mean velocity/end-tidal CO2 (DeltaMV/DeltaetCO2) differed significantly between hypertensive subjects and controls (p = 0.03 and p = 0.02, respectively). CONCLUSION: Ergometer cycling combined with TCD revealed altered vasoreactivity, therefore this may be a sensitive method for the detection of early hemodynamic impairment in nontreated hypertensive subjects. Copyright 2001 S. Karger AG, Basel
PURPOSE: To evaluate the diagnostic value of a combined method, i.e. ergometer cycling with continuous bilateral transcranial Doppler monitoring (TCD) to detect cerebral hemodynamic abnormalities in recently diagnosed hypertensivepatients. METHODS: 30 neurologically symptom-free, nontreated patients with essential hypertension and 30 age- and sex-matched controls were studied. Carotid ultrasound, resting ECG and blood parameters were investigated. Cycling ergometry was performed according to the WHO protocol. Blood pressure, heart rate, end-tidal CO2 (etCO2) and bilateral middle cerebral artery (MCA) blood flow velocity (MV) were monitored. RESULTS: At rest, MV in the MCA did not differ significantly between controls and hypertensive subjects. MV continuously increased in controls until the end of loading whereas a plateau was reached at 4 min in hypertensive subjects. During 6 min of cycling, the time course of absolute values of MV in the MCA and that of the changes in the ratio of mean velocity/end-tidal CO2 (DeltaMV/DeltaetCO2) differed significantly between hypertensive subjects and controls (p = 0.03 and p = 0.02, respectively). CONCLUSION: Ergometer cycling combined with TCD revealed altered vasoreactivity, therefore this may be a sensitive method for the detection of early hemodynamic impairment in nontreated hypertensive subjects. Copyright 2001 S. Karger AG, Basel
Authors: Felicia C Chow; W John Boscardin; Claire Mills; Nerissa Ko; Courtney Carroll; Richard W Price; Steven Deeks; Farzaneh A Sorond; Priscilla Y Hsue Journal: AIDS Date: 2016-01-02 Impact factor: 4.177
Authors: Enikő Csikai; Mónika Andrejkovics; Bernadett Balajthy-Hidegh; Gergely Hofgárt; László Kardos; Ágnes Diószegi; Róbert Rostás; Katalin Réka Czuriga-Kovács; Éva Csongrádi; László Csiba Journal: Medicine (Baltimore) Date: 2019-08 Impact factor: 1.817