Literature DB >> 11641161

Fast three-point dixon MR imaging using low-resolution images for phase correction: a comparison with chemical shift selective fat suppression for pediatric musculoskeletal imaging.

F J Rybicki1, T Chung, J Reid, D Jaramillo, R V Mulkern, J Ma.   

Abstract

OBJECTIVE: The purpose of this study is to describe and to implement a new fast three-point Dixon MR imaging sequence with online image reconstruction, and to compare this sequence with conventional chemical shift selective (CHESS) suppression of fat in pediatric musculoskeletal imaging. SUBJECTS AND METHODS: A three-point Dixon technique using a fast spin-echo sequence with a new phase-correction algorithm providing online image reconstruction was implemented on a 1.5-T scanner. Twelve pediatric patients and young adults were imaged with both the new three-point Dixon and conventional CHESS sequences. Three radiologists un-aware of imaging parameters and clinical information independently scored the homogeneity of fat suppression and conspicuity of abnormality using a four-point system. An additional comparison between the two techniques was made using a phantom.
RESULTS: The three-point Dixon method showed superior fat suppression and lesion conspicuity (p < 0.001), particularly in the hands and feet, where CHESS is prone to inconsistent fat suppression. The phantom study showed no significant difference in the ratio of suppressed fat signal to background noise and more homogeneous fat suppression using the three-point Dixon method.
CONCLUSION: Compared with CHESS, the new fast three-point Dixon sequence with online image reconstruction provides superior fat suppression and lesion conspicuity and can be routinely used in pediatric musculoskeletal imaging.

Entities:  

Mesh:

Year:  2001        PMID: 11641161     DOI: 10.2214/ajr.177.5.1771019

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  9 in total

Review 1.  Review of key concepts in magnetic resonance physics.

Authors:  Michael M Moore; Taylor Chung
Journal:  Pediatr Radiol       Date:  2017-04-13

Review 2.  The Dixon technique for MRI of the bone marrow.

Authors:  Niels van Vucht; Rodney Santiago; Bianca Lottmann; Ian Pressney; Dorothee Harder; Adnan Sheikh; Asif Saifuddin
Journal:  Skeletal Radiol       Date:  2019-07-15       Impact factor: 2.199

Review 3.  Fat-containing soft-tissue masses in children.

Authors:  Elizabeth F Sheybani; Eric P Eutsler; Oscar M Navarro
Journal:  Pediatr Radiol       Date:  2016-11-19

4.  Clinical experience with two-point mDixon turbo spin echo as an alternative to conventional turbo spin echo for magnetic resonance imaging of the pediatric knee.

Authors:  Bamidele F Kammen; Eric M Padua; S Pinar Karakas; R Ward Hagar; Dave M Hitt; Nirav K Pandya; Taylor Chung
Journal:  Pediatr Radiol       Date:  2019-02-06

Review 5.  Fat-suppression techniques for 3-T MR imaging of the musculoskeletal system.

Authors:  Filippo Del Grande; Francesco Santini; Daniel A Herzka; Michael R Aro; Cooper W Dean; Garry E Gold; John A Carrino
Journal:  Radiographics       Date:  2014 Jan-Feb       Impact factor: 5.333

6.  High-resolution, large dynamic range field map estimation.

Authors:  Joseph Dagher; Timothy Reese; Ali Bilgin
Journal:  Magn Reson Med       Date:  2013-02-11       Impact factor: 4.668

7.  Usefulness of the fast spin-echo three-point Dixon (mDixon) image of the knee joint on 3.0-T MRI: comparison with conventional fast spin-echo T2 weighted image.

Authors:  Hee J Park; So Y Lee; Myung H Rho; Eun C Chung; Jin H Ahn; Jai H Park; In S Lee
Journal:  Br J Radiol       Date:  2016-03-23       Impact factor: 3.039

8.  Improved nerve conspicuity with water-weighting and denoising in two-point Dixon magnetic resonance neurography.

Authors:  Ek T Tan; Sophie C Queler; Bin Lin; Yoshimi Endo; Alissa J Burge; Julia Sternberg; Hollis G Potter; Darryl B Sneag
Journal:  Magn Reson Imaging       Date:  2021-03-20       Impact factor: 3.130

9.  Efficiency of Fat Suppression in T1-Weighted Inner Ear Magnetic Resonance Imaging: Multipoint Dixon Method Versus Hybrid Techniques.

Authors:  Pinar Cakmak; Duygu Herek; Ahmet Baki Yagci; Ergin Sagtas; Furkan Ufuk; Vefa Çakmak
Journal:  Curr Med Imaging       Date:  2021
  9 in total