Literature DB >> 1163657

Reflex sympathetic changes in aortic diastolic pressure-diameter relationship.

M Pagani, P J Schwartz, V S Bishop, A Malliani.   

Abstract

In anesthetized vagotomized cats with the chest opened and artificially ventilated, aortic blood pressure (AP) and external diameter (AD; ultrasound technique) were measured in the proximal third of the descending thoracic aorta. Slow sinusoidal oscillations (0.2-0.3 Hz in aortic volume were produced by a piston pump connected to a femoral artery. Diastolic pressure-diameter relationship (PDR) curves were obtained during control conditions and during stimulation of either the cut central end of the left inferior cardiac nerve (ICN) or the decentralized thoracic sympathetic chain (SC). In six cats with both carotid arteries occluded ICN stimulation reflexly shifted the PDR curves to lower diameters for any given pressure (mean deltaAD 3.2% at control AP). A smaller response to ICN stimulation was obtained in five cats with one patent carotid artery (mean deltaAD 2.3% at control AP). Stimulation of sympathetic efferents to the aorta (SC) caused similar responses in five animals (mean deltaAD 3.4% at control AP). This reflex control of the thoracic aorta may be involved in cardioaortic coupling and may influence the sensitivity of aortic mechanoreceptors.

Entities:  

Mesh:

Year:  1975        PMID: 1163657     DOI: 10.1152/ajplegacy.1975.229.2.286

Source DB:  PubMed          Journal:  Am J Physiol        ISSN: 0002-9513


  8 in total

1.  The use of nitroprusside to characterize aortic pressure-diameter relationships.

Authors:  J J Ferguson; S Momomura; P Sahagian; M J Miller; R G McKay
Journal:  Tex Heart Inst J       Date:  1989

2.  Afferent sympathetic nerve fibres with aortic endings.

Authors:  A Malliani; M Pagani
Journal:  J Physiol       Date:  1976-12       Impact factor: 5.182

3.  In vitro and finite-element model investigation of the conductance technique for measurement of aortic segmental volume.

Authors:  D A Hettrick; J H Battocletti; J J Ackmann; J H Linehan; D C Warltier
Journal:  Ann Biomed Eng       Date:  1996 Nov-Dec       Impact factor: 3.934

4.  A novel set-up for the ex vivo analysis of mechanical properties of mouse aortic segments stretched at physiological pressure and frequency.

Authors:  Arthur J A Leloup; Cor E Van Hove; Ammar Kurdi; Sofie De Moudt; Wim Martinet; Guido R Y De Meyer; Dorien M Schrijvers; Gilles W De Keulenaer; Paul Fransen
Journal:  J Physiol       Date:  2016-08-02       Impact factor: 5.182

5.  The effects of phenoxybenzamine on the aortic pressure-diameter relationship in dogs.

Authors:  D N Stone; J P Dujardin
Journal:  Experientia       Date:  1982-02-15

6.  Determination of the mean cross-sectional area of the thoracic aorta using a double indicator dilution technique.

Authors:  L Kornet; J R Jansen; E J Gussenhoven; A Versprille
Journal:  Pflugers Arch       Date:  1996-10       Impact factor: 3.657

7.  Vascular smooth muscle cell contraction and relaxation in the isolated aorta: a critical regulator of large artery compliance.

Authors:  Arthur J A Leloup; Cor E Van Hove; Sofie De Moudt; Guido R Y De Meyer; Gilles W De Keulenaer; Paul Fransen
Journal:  Physiol Rep       Date:  2019-02

Review 8.  Arterial Stiffness.

Authors:  Alberto Avolio
Journal:  Pulse (Basel)       Date:  2013-03-11
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.