Literature DB >> 11606961

Frictional behavior of stainless steel bracket-wire combinations subjected to small oscillating displacements.

G Willems1, K Clocheret, J P Celis, G Verbeke, E Chatzicharalampous, C Carels.   

Abstract

In orthodontic treatment, sliding is frequently used to cause tooth movement. Inherent to this technique is the generation of a counteracting frictional force. In this pilot study, a fretting test consisting of reciprocating tangential displacements was used to investigate test parameters influencing frictional forces during sliding processes. Tests were run at a normal load of 2 N and a frequency of 1 Hz for tangential displacement strokes of 200 microm. Stainless steel orthodontic wires with cross-sections of .017 x .025 in (W17) and .018 x .025 in (W18), and brackets with slot sizes of .018 in (B18) and .022 in (B22) were used. A specific centered positioning method was developed to achieve a parallel alignment of the wire and the bracket slot. The experimental results indicated the significant role of the centered positioning method on the friction value. Implementation of the centered positioning method resulted in a friction force ranging from 0.89 N to 0.97 N at a 200 microm displacement amplitude and 1 Hz frequency, corresponding to a coefficient of friction ranging from 0.45 to 0.49 for the B18-W17 and the B22-W17 bracket-wire combinations, respectively. When the centered positioning method was not used, significantly higher values for the coefficient of friction were found for both bracket-wire combinations. The slot-filling, bracket-wire combinations (B18-W18 and B22-W22) resulted in an increased coefficient of friction and therefore are not recommended as sliding systems.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11606961     DOI: 10.1067/mod.2001.116088

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  3 in total

1.  Coating NiTi archwires with diamond-like carbon films: reducing fluoride-induced corrosion and improving frictional properties.

Authors:  S Y Huang; J J Huang; T Kang; D F Diao; Y Z Duan
Journal:  J Mater Sci Mater Med       Date:  2013-06-21       Impact factor: 3.896

2.  The clinical and laboratory effects of bracket type during canine distalization with sliding mechanics.

Authors:  A Alper Oz; Nursel Arici; Selim Arici
Journal:  Angle Orthod       Date:  2011-08-29       Impact factor: 2.079

3.  Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique.

Authors:  Nursel Arici; Berat Serdar Akdeniz; Selim Arici
Journal:  Korean J Orthod       Date:  2015-01-26       Impact factor: 1.372

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.