Literature DB >> 11605868

A comparison of 3 computerized Bolton tooth-size analyses with a commonly used method.

J J Tomassetti1, L J Taloumis, J M Denny, J R Fischer.   

Abstract

Four methods of conducting overall and anterior Bolton tooth-size analyses were compared using 22 (11 pretreatment and 11 posttreatment) sets of models. No more than 3 mm of crowding existed in any of the models, and all were in good condition. An analysis employing vernier calipers was completed 3 times to set a standard. Pearson correlation coefficients revealed a high degree of intra-operator reliability with mean R values of 0.930 and 0.843 for the overall and anterior discrepancies, respectively. The mean Vernier caliper results were compared with each of the following computerized methods: QuickCeph, Hamilton Arch Tooth System (HATS), and OrthoCad. No statistically significant error was present for any of the methods using repeated-measures analysis of variance testing and paired t-tests (p < .05). Clinically significant differences (>1.5 mm) were present for each method. Absolute differences were calculated, and linear regression and R values were determined. The HATS analysis had the highest degree of correlation (R = 0.885 for overall and 0.825 for anterior), followed by OrthoCad (R = 0.715, 0.574), and QuickCeph (R = 0.432, 0.439). Each method also was compared based on the time required to complete each analysis. The QuickCeph was the fastest (1.85 minutes) followed by HATS (3.40 minutes), OrthoCad (5.37 minutes), and Vernier caliper (8.06 min).

Mesh:

Year:  2001        PMID: 11605868     DOI: 10.1043/0003-3219(2001)071<0351:ACOCBT>2.0.CO;2

Source DB:  PubMed          Journal:  Angle Orthod        ISSN: 0003-3219            Impact factor:   2.079


  22 in total

1.  Orthodontic study cast analysis--reproducibility of recordings and agreement between conventional and 3D virtual measurements.

Authors:  Anders P G Sjögren; Jan E Lindgren; Jan A V Huggare
Journal:  J Digit Imaging       Date:  2009-06-13       Impact factor: 4.056

2.  Accuracy and reproducibility of measurements on plaster models and digital models created using an intraoral scanner.

Authors:  Leonardo Tavares Camardella; Hero Breuning; Oswaldo de Vasconcellos Vilella
Journal:  J Orofac Orthop       Date:  2017-01-10       Impact factor: 1.938

3.  [Fabrication and accuracy research on 3D printing dental model based on cone beam computed tomography digital modeling].

Authors:  Hui-Rong Zhang; Le-Feng Yin; Yan-Li Liu; Li-Yi Yan; Ning Wang; Gang Liu; Xiao-Li An; Bin Liu
Journal:  Hua Xi Kou Qiang Yi Xue Za Zhi       Date:  2018-04-01

4.  Comparison of orthodontic measurements on dental plaster casts and 3D scans.

Authors:  Johanna Radeke; Cynthia von der Wense; Bernd G Lapatki
Journal:  J Orofac Orthop       Date:  2014-07-06       Impact factor: 1.938

5.  Virtual setup: application in orthodontic practice.

Authors:  Leonardo T Camardella; Eduardo Kant C Rothier; Oswaldo V Vilella; Edwin M Ongkosuwito; Karel Hero Breuning
Journal:  J Orofac Orthop       Date:  2016-09-05       Impact factor: 1.938

6.  Reliability of measurements made on scanned cast models using the 3 Shape R 700 scanner.

Authors:  L S Lemos; I M C R Rebello; C J Vogel; M C Barbosa
Journal:  Dentomaxillofac Radiol       Date:  2015-02-27       Impact factor: 2.419

7.  Reliability of Bolton analysis evaluation in tridimensional virtual models.

Authors:  Marianna Mendonca Brandão; Marcio Costal Sobral; Carlos Jorge Vogel
Journal:  Dental Press J Orthod       Date:  2015-10

8.  REGISTRATION OF ORTHODONTIC DIGITAL MODELS.

Authors:  Dan Grauer; Lucia H Cevidanes; Donald Tyndall; Martin A Styner; Patrick M Flood; William R Proffit
Journal:  Craniofac Growth Ser       Date:  2011

9.  Efficiency and Accuracy of Three-Dimensional Models Versus Dental Casts: A Clinical Study.

Authors:  Hakan Yılmaz; Fethiye Çakmak Özlü; Carmen Karadeniz; Ersan İlsay Karadeniz
Journal:  Turk J Orthod       Date:  2019-12-01

10.  Evaluation of the use of digital study models in postgraduate orthodontic programs in the United States and Canada.

Authors:  Shruti Shastry; Jae Hyun Park
Journal:  Angle Orthod       Date:  2013-06-06       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.