Literature DB >> 11604338

Endovascular AAA repair in patients with renal insufficiency: strategies for reducing adverse renal events.

J P Carpenter1, R M Fairman, C F Barker, M A Golden, O C Velazquez, M E Mitchell, R A Baum.   

Abstract

Vascular imaging, usually employing nephrotoxic contrast agents is relied upon for all aspects of endovascular AAA repair causing some to consider renal insufficiency a relative contraindication. We sought to determine if endovascular AAA evaluation and repair could be successfully accomplished by minimally or non-nephrotoxic modalities. Records and results for 98 consecutive patients undergoing endovascular AAA repair were reviewed. Patients requiring dialysis preoperatively were excluded (N=3). The average volume of iodinated contrast agent employed for intraoperative imaging was 152 cc (35-420 cc). Twenty patients (20%) had baseline renal insufficiency (serum creatinine > or =1.3 mg/dl). A rise in serum creatinine above baseline was observed in 23 (24%) patients following repair; for 15 (16%) this was permanent. Creatinine rise occurred in patients with both normal (15) and abnormal (8) baseline values (P=0.09). Rise in creatinine was independent of contrast volume employed and of the use of infrarenal vs suprarenal device fixation (P>0.05). Two (2%) patients required permanent dialysis, one of which had a normal baseline creatinine and unclear etiology for renal failure, the other had a baseline creatinine of 2 and required device placement over an accessory renal artery. Strategies to minimize the use of nephrotoxic contrast for patients with renal insufficiency included the use of MRA, rather than contrast-CT for pre and postoperative imaging (7, 35%) and use of Gadolinium rather than iodinated contrast for performance of intraoperative arteriography (5, 25%). Endovascular grafts were successfully designed and implanted based upon MRA as the sole preoperative imaging modality in every case in which it was attempted (7). Mortality was not significantly different between those with and without abnormal baseline renal function (P>0.05). Adverse events (access failures, arterial injuries, blood loss, endoleaks) were not significantly correlated with baseline renal insufficiency, rise in creatinine from baseline, use of MRA or intraoperative Gadolinium angiography (P>0.05).Pre- and postoperative evaluation and performance of endovascular AAA repair can be accomplished in patients with renal insufficiency without increasing the rate of mortality or adverse events employing a strategy which minimizes the use of nephrotoxic contrast agents, relying upon Gadolinium arteriography and MRA. Endovascular grafts can be successfully planned and followed employing MRA as the sole imaging modality.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11604338     DOI: 10.1016/s0967-2109(01)00085-0

Source DB:  PubMed          Journal:  Cardiovasc Surg        ISSN: 0967-2109


  7 in total

1.  A Retrospective Analysis of Comparison of General Versus Regional Anaesthesia for Endovascular Repair of Abdominal Aortic Aneurysm.

Authors:  Özgür Yağan; Kadir Özyılmaz; Nilay Taş; Volkan Hancı
Journal:  Turk J Anaesthesiol Reanim       Date:  2014-09-09

2.  Efficacy Analysis of a Script-based Guide for EVAR Execution: is it Possible to Reduce Patient Exposure to Contrast, Operative Time and Blood Loss even when Advanced Technologies are not Available?

Authors:  Giovani José Dal Poggetto Molinari; Ana Terezinha Guillaumon; Andréia Marques de Oliveira Dalbem
Journal:  Braz J Cardiovasc Surg       Date:  2015 Nov-Dec

3.  Changes in inflammatory response after endovascular treatment for type B aortic dissection.

Authors:  Bernice L Y Cheuk; Y C Chan; Stephen W K Cheng
Journal:  PLoS One       Date:  2012-05-24       Impact factor: 3.240

4.  Complications after endovascular stent-grafting of thoracic aortic diseases.

Authors:  Gabriele Piffaretti; Matteo Tozzi; Chiara Lomazzi; Nicola Rivolta; Roberto Caronno; Patrizio Castelli
Journal:  J Cardiothorac Surg       Date:  2006-09-12       Impact factor: 1.637

Review 5.  Anesthetic considerations for endovascular abdominal aortic aneurysm repair.

Authors:  Harikrishnan Kothandan; Geoffrey Liew Haw Chieh; Shariq Ali Khan; Ranjith Baskar Karthekeyan; Shah Shitalkumar Sharad
Journal:  Ann Card Anaesth       Date:  2016 Jan-Mar

6.  Image fusion performed with noncontrast computed tomography scans during endovascular aneurysm repair.

Authors:  Teresa Martin-Gonzalez; Adrien Hertault; Blandine Maurel; Marco Midulla; Mohammad Saeed Kilani; Stephan Haulon
Journal:  J Vasc Surg Cases       Date:  2015-03-18

7.  Bicarbonates for the prevention of postoperative renal failure in endovascular aortic aneurysm repair: a randomized pilot trial.

Authors:  Véronique Brulotte; François A Leblond; Stéphane Elkouri; Eric Thérasse; Vincent Pichette; Pierre Beaulieu
Journal:  Anesthesiol Res Pract       Date:  2013-06-12
  7 in total