Abstract

AIM: The purpose of this study was to compare several parameters of root canal preparation using two different rotary nickel-titanium instruments: HERO 642 (Micro-Mega, Besancon, France) and Quantec SC (Tycom, Irvine, CA, USA).
METHODOLOGY: Fifty extracted mandibular molars with root canal curvatures between 20 micro and 40 micro were imbedded into a muffle system. All root canals were prepared to size 45 (Quantec SC), or 40 (HERO 642), respectively. The following parameters were evaluated: straightening of curved root canals, postoperative root canal diameter, safety issues (file fractures, perforations, apical blockages, loss of working length), cleaning ability, and working time.
RESULTS: Both Ni-Ti-systems maintained curvature well; the mean degree of straightening was 2.3 degrees for Quantec SC and 1.6 degrees for HERO 642. Most procedural incidents occurred with Quantec SC instruments (five fractures, three apical blockages, eight cases of loss of working length), HERO 642 preparation resulted in three blockages and one perforation. Following preparation with HERO 642, 63% of the root canals showed a round, 24% an oval, and 17% an irregular diameter; Quantec SC preparations resulted in a round diameter in 24% of the cases, oval shape in 29%, and irregular cross-section in 47% of the cases. Mean working time was shorter for HERO 642 (52 s) than for Quantec (117 s). Cleanliness of the root canal walls was investigated under the SEM using a five-score system for debris and smear layer. For debris HERO 642 achieved better results (80% scores 1 and 2) than Quantec SC (76%). The results for smear layer were similar: cleaner root canal walls were found after preparation with HERO 642 (53% scores 1 and 2), followed by Quantec SC (41%).
CONCLUSIONS: Both systems respected original root canal curvature well and showed good cleaning ability; Quantec SC showed deficiencies in terms of safety.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11601772     DOI: 10.1046/j.1365-2591.2001.00431.x

Source DB:  PubMed          Journal:  Int Endod J        ISSN: 0143-2885            Impact factor:   5.264


  23 in total

1.  Appearance of the root canal walls after preparation with NiTi rotary instruments: a comparative SEM investigation.

Authors:  Carlo Prati; Federico Foschi; Cesare Nucci; Lucio Montebugnoli; Silvia Marchionni
Journal:  Clin Oral Investig       Date:  2004-02-04       Impact factor: 3.573

2.  Smear layer and debris removal using manual Ni-Ti files compared with rotary Protaper Ni- Ti files - An In-Vitro SEM study.

Authors:  J M V Raghavendra Reddy; Prasanna Latha; Basavana Gowda; Varadendra Manvikar; D Benal Vijayalaxmi; Kalyana Chakravarthi Ponangi
Journal:  J Int Oral Health       Date:  2014-02-26

3.  Canal-centering ability: An endodontic challenge.

Authors:  Deivanayagam Kandaswamy; Nagendrababu Venkateshbabu; Ilango Porkodi; Gali Pradeep
Journal:  J Conserv Dent       Date:  2009-01

4.  Comparative evaluation of surface characteristics of dentinal walls with and without using plastic finishing file.

Authors:  Smita Singh; Neeraj Nigam
Journal:  J Conserv Dent       Date:  2010-04

5.  Evaluation of the efficacy of rotary vs. hand files in root canal preparation of primary teeth in vitro using CBCT.

Authors:  P K Musale; S A V Mujawar
Journal:  Eur Arch Paediatr Dent       Date:  2013-07-27

6.  Influence of different methods of cervical flaring on establishment of working length.

Authors:  Dieison Nardi Lazzaretti; Bernardo Alievi Camargo; Alvaro Della Bona; Volmir João Fornari; José Roberto Vanni; Flares Baratto Filho
Journal:  J Appl Oral Sci       Date:  2006-10       Impact factor: 2.698

7.  Centering ability and dentin removal of rotary systems in curved root canals.

Authors:  Saeed Moradi; Ali Talati; Ali Monajem Zadeh
Journal:  Iran Endod J       Date:  2009-07-06

8.  Cone-beam computed tomography analysis of curved root canals after mechanical preparation with three nickel-titanium rotary instruments.

Authors:  Samia M Elsherief; Mohamed K Zayet; Ibrahim M Hamouda
Journal:  J Biomed Res       Date:  2013-06-25

9.  In vitro evaluation of root canal preparation with two rotary instrument systems - Pro Taper and Hero Shaper.

Authors:  Carola Pentelescu; Loredana Colceriu; Ovidiu Pastrav; Carina Culic; Radu Chisnoiu
Journal:  Clujul Med       Date:  2015-07-01

Review 10.  Rotary endodontics in primary teeth - A review.

Authors:  Sageena George; S Anandaraj; Jyoti S Issac; Sheen A John; Anoop Harris
Journal:  Saudi Dent J       Date:  2015-11-22
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.