Literature DB >> 11601732

Intimal hyperplasia and wall shear in arterial bypass graft distal anastomoses: an in vivo model study.

R S Keynton1, M M Evancho, R L Sims, N V Rodway, A Gobin, S E Rittgers.   

Abstract

The observation of intimal hyperplasia at bypass graft anastomoses has suggested a potential interaction between local hemodynamics and vascular wall response. Wall shear has been particularly implicated because of its known effects upon the endothelium of normal vessels and, thus, was examined as to its possible role in the development of intimal hyperplasia in arterial bypass graft distal anastomoses. Tapered (4-7 mm I.D.) e-PTFE synthetic grafts 6 cm long were placed as bilateral carotid artery bypasses in six adult, mongrel dogs weighing between 25 and 30 kg with distal anastomotic graft-to-artery diameter ratios (DR) of either 1.0 or 1.5. Immediately following implantation, simultaneous axial velocity measurements were made in the toe and artery floor regions in the plane of the anastomosis at radial increments of 0.35 mm, 0.70 mm, and 1.05 mm using a specially designed 20 MHz triple crystal ultrasonic wall shear rate transducer Mean, peak, and pulse amplitude wall shear rates (WSRs), their absolute values, the spatial and temporal wall shear stress gradients (WSSG), and the oscillatory shear index (OSI) were computed from these velocity measurements. All grafts were harvested after 12 weeks implantation and measurements of the degree of intimal hyperplasia (IH) were made along the toe region and the artery floor of the host artery in 1 mm increments. While some IH occurred along the toe region (8.35+/-23.1 microm) and was significantly different between DR groups (p<0.003), the greatest amount occurred along the artery floor (81.6+/-106.5 microm, mean +/- S.D.) (p < 0.001) although no significant differences were found between DR groups. Linear regressions were performed on the paired IH and mean, peak, and pulse amplitude WSR data as well as the absolute mean, peak, and pulse amplitude WSR data from all grafts. The mean and absolute mean WSRs showed a modest correlation with IH (r = -0.406 and -0.370, respectively) with further improvements seen (r = -0.482 and -0.445, respectively) when using an exponential relationship. The overall best correlation was seen against an exponential function of the OSI (r = 0.600). Although these correlation coefficients were not high, they were found to be statistically significant as evidenced by the large F-statistic obtained. Finally, it was observed that over 75 percent of the IH occurred at or below a mean WSR value of 100 s(-1) while approximately 92 percent of the IH occurred at or below a mean WSR equal to one-half that of the native artery. Therefore, while not being the only factor involved, wall shear (and in particular, oscillators wall shear) appears to provide a stimulus for the development of anastomotic intimal hyperplasia.

Entities:  

Mesh:

Year:  2001        PMID: 11601732     DOI: 10.1115/1.1389461

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  14 in total

1.  Hypoxia-induced phenotypic switch of fibroblasts to myofibroblasts through a matrix metalloproteinase 2/tissue inhibitor of metalloproteinase-mediated pathway: implications for venous neointimal hyperplasia in hemodialysis access.

Authors:  Sanjay Misra; Alex A Fu; Khamal D Misra; Uday M Shergill; Edward B Leof; Debabrata Mukhopadhyay
Journal:  J Vasc Interv Radiol       Date:  2010-06       Impact factor: 3.464

2.  Patient-specific multiscale modeling of blood flow for coronary artery bypass graft surgery.

Authors:  Sethuraman Sankaran; Mahdi Esmaily Moghadam; Andrew M Kahn; Elaine E Tseng; Julius M Guccione; Alison L Marsden
Journal:  Ann Biomed Eng       Date:  2012-04-27       Impact factor: 3.934

3.  Evaluation of the hemodynamics in straight 6-mm and tapered 6- to 8-mm grafts as upper arm hemodialysis vascular access.

Authors:  M Sarmast; H Niroomand-Oscuii; F Ghalichi; E Samiei
Journal:  Med Biol Eng Comput       Date:  2014-08-12       Impact factor: 2.602

4.  Longer coronary anastomosis provides lower energy loss in coronary artery bypass grafting.

Authors:  Hiroyuki Tsukui; Manabu Shinke; Young Kwang Park; Kenji Yamazaki
Journal:  Heart Vessels       Date:  2016-08-02       Impact factor: 2.037

5.  Sensitivity of CFD based hemodynamic results in rabbit aneurysm models to idealizations in surrounding vasculature.

Authors:  Zijing Zeng; David F Kallmes; Michael J Durka; Yonghong Ding; Debra Lewis; Ramanathan Kadirvel; Anne M Robertson
Journal:  J Biomech Eng       Date:  2010-09       Impact factor: 2.097

6.  Evolution of shear stress, protein expression, and vessel area in an animal model of arterial dilatation in hemodialysis grafts.

Authors:  Sanjay Misra; Alex A Fu; Khamal D Misra; James F Glockner; Debabrata Mukhopadyay
Journal:  J Vasc Interv Radiol       Date:  2010-01       Impact factor: 3.464

7.  Double cobra head technique of distal coronary anastomosis.

Authors:  Vijayanand Palanisamy; Mithun Sundararaaja Ravikumar; Shilpa Shree; Antony Leander Sathiaraj; Anbarasu Mohanraj; Valikapthalil Mathew Kurian
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2021-09-28

8.  Comparison of near-wall hemodynamic parameters in stented artery models.

Authors:  Nandini Duraiswamy; Richard T Schoephoerster; James E Moore
Journal:  J Biomech Eng       Date:  2009-06       Impact factor: 2.097

9.  Extracellular signal-regulated kinase activation and endothelin-1 production in human endothelial cells exposed to vibration.

Authors:  Charles R White; Mark A Haidekker; Hazel Y Stevens; John A Frangos
Journal:  J Physiol       Date:  2004-01-14       Impact factor: 5.182

10.  Biologically active fragment of a human tRNA synthetase inhibits fluid shear stress-activated responses of endothelial cells.

Authors:  E Tzima; J S Reader; M Irani-Tehrani; K L Ewalt; M A Schwartz; P Schimmel
Journal:  Proc Natl Acad Sci U S A       Date:  2003-11-20       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.