Literature DB >> 11601131

Accuracy of thyroid fine-needle aspiration using receiver operator characteristic curves.

A A Renshaw1.   

Abstract

Although many large series demonstrate the effectiveness of thyroid fine-needle aspiration (FNA), measuring its accuracy has been suboptimal owing to inappropriate statistical methods. All thyroid fine-needle aspirates were correlated with corresponding histologic and cytologic follow-up for a 4-year period, and the accuracy was determined using receiver operator characteristic curves, which allow inclusion of nondiagnostic and indeterminate cases. There were 1,085 cases, 291 with follow-up. The overall accuracy was 0.90 +/- 0.02 for a single aspiration session. A nondiagnostic aspirate was associated with a significant risk of malignancy (16%). However, 70% of patients who underwent reaspiration had adequate and negative results, and reaspiration significantly increased overall accuracy. Subcategorizing the nondiagnostic category did not affect accuracy, but did define categories with a significantly different change of a negative diagnosis on repeated aspiration. Although subcategories of papillary carcinoma were associated with significantly different risks of carcinoma (40% vs 81%), they did not significantly improve overall accuracy. Receiver operator characteristic curves can be used to define the accuracy of thyroid FNA. This method demonstrates significantly increased accuracy with repeated aspiration of nondiagnostic cases and demonstrates that subcategorization does not improve the overall accuracy of the test.

Entities:  

Mesh:

Year:  2001        PMID: 11601131     DOI: 10.1309/M3K5-23C2-455E-0HB5

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  6 in total

1.  Application of magnetic-resonance-spectroscopy- based metabolomics to the fine-needle aspiration diagnosis of papillary thyroid carcinoma.

Authors:  Kate W Jordan; Christen B Adkins; Leo L Cheng; William C Faquin
Journal:  Acta Cytol       Date:  2011-12-09       Impact factor: 2.319

2.  A prospective study evaluating the accuracy of using combined clinical factors and candidate diagnostic markers to refine the accuracy of thyroid fine needle aspiration biopsy.

Authors:  Aarti Mathur; Julie Weng; Willieford Moses; Seth M Steinberg; Reza Rahbari; Reza Rahabari; Mio Kitano; Elham Khanafshar; Britt-Marie Ljung; Quan-Yang Duh; Orlo H Clark; Electron Kebebew
Journal:  Surgery       Date:  2010-12       Impact factor: 3.982

3.  Fine needle aspiration cytology of thyroid lesions and its correlation with histopathology in a series of 248 patients.

Authors:  Renu Sukumaran; Jayasree Kattoor; K Raveendran Pillai; Preethi T Ramadas; Nileena Nayak; Thara Somanathan; Nebu Abraham George; Paul Sebastian
Journal:  Indian J Surg Oncol       Date:  2014-08-09

4.  BREASTAID: Clinical results from early development of a clinical decision rule for palpable solid breast masses.

Authors:  Janet Rose Osuch; Mathew J Reeves; Dorothy R Pathak; Tosca Kinchelow
Journal:  Ann Surg       Date:  2003-11       Impact factor: 12.969

5.  The National Cancer Institute Thyroid fine needle aspiration state of the science conference: a summation.

Authors:  Zubair W Baloch; Edmund S Cibas; Douglas P Clark; Lester J Layfield; Britt-Marie Ljung; Martha Bishop Pitman; Andrea Abati
Journal:  Cytojournal       Date:  2008-04-07       Impact factor: 2.091

6.  Evaluation of malignancy with thyroid imaging reporting and data system (TI-RADS) in thyroid nodules with persistent nondiagnostic cytology

Authors:  Hüsniye Başer; Oya Topaloğlu; Sevgul Fakı; Afra Alkan; Mustafa Ömer Yazıcıoğlu; Hayriye Tatlı Doğan; İbrahim Kılınç; Reyhan Ersoy; Bekir Çakır
Journal:  Turk J Med Sci       Date:  2019-06-18       Impact factor: 0.973

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.