Literature DB >> 11600247

An outbreak of methicillin resistant Staphylococcus aureus on a burn unit: potential role of contaminated hydrotherapy equipment.

J M Embil1, J A McLeod, A M Al-Barrak, G M Thompson, F Y Aoki, E J Witwicki, M F Stranc, A M Kabani, D R Nicoll, L E Nicolle.   

Abstract

OBJECTIVE: To report a multi-institution outbreak caused by a single strain of methicillin-resistant Staphylococcus aureus (MRSA). OUTBREAK: Between September 19 and November 20, 1996 an index case and five secondary cases of nosocomial MRSA occurred on a 26 bed adult plastic surgery/burn unit (PSBU) at a tertiary care teaching hospital. Between November 11 and December 23, 1996, six additional cases were identified at a community hospital. One of the community hospital cases was transferred from the PSBU. All strains were identical by pulsed-field gel electrophoresis. MRSA may have contributed to skin graft breakdown in one case, and delayed wound healing in others. Patients required 2 to 226 isolation days. CONTROL MEASURES: A hand held shower and stretcher for showering in the hydrotherapy room of the PSBU were culture positive for the outbreak strain, and the presumed means of transmission. Replacement of stretcher showering with bedside sterile burn wound compresses terminated the outbreak. The PSBU was closed to new admissions and transfers out for 11 days during the investigation. Seven of 12 patients had effective decolonization therapy.
CONCLUSION: Environmental contamination is a potential source of nosocomial MRSA transmission on a burn unit. Notification among institutions and community care providers of shared patients infected or colonized with an antimicrobial resistant microorganism is necessary.

Entities:  

Mesh:

Year:  2001        PMID: 11600247     DOI: 10.1016/s0305-4179(01)00045-6

Source DB:  PubMed          Journal:  Burns        ISSN: 0305-4179            Impact factor:   2.744


  17 in total

1.  Burn wound cleansing - a myth or a scientific practice.

Authors:  S Hayek; A El Khatib; B Atiyeh
Journal:  Ann Burns Fire Disasters       Date:  2010-03-31

2.  2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care Settings.

Authors:  Jane D Siegel; Emily Rhinehart; Marguerite Jackson; Linda Chiarello
Journal:  Am J Infect Control       Date:  2007-12       Impact factor: 2.918

Review 3.  Infection control issues in older adults.

Authors:  Lona Mody
Journal:  Clin Geriatr Med       Date:  2007-08       Impact factor: 3.076

Review 4.  MRSA and the environment: implications for comprehensive control measures.

Authors:  N Cimolai
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2008-02-14       Impact factor: 3.267

Review 5.  Topical antimicrobials for burn infections - an update.

Authors:  Mert Sevgi; Ani Toklu; Daniela Vecchio; Michael R Hamblin
Journal:  Recent Pat Antiinfect Drug Discov       Date:  2013-12

Review 6.  Management and prevention of drug resistant infections in burn patients.

Authors:  Roohi Vinaik; Dalia Barayan; Shahriar Shahrokhi; Marc G Jeschke
Journal:  Expert Rev Anti Infect Ther       Date:  2019-08-04       Impact factor: 5.091

Review 7.  Topical antimicrobials for burn wound infections.

Authors:  T Dai; Y Y Huang; S K Sharma; J T Hashmi; D B Kurup; M R Hamblin
Journal:  Recent Pat Antiinfect Drug Discov       Date:  2010-06

Review 8.  Infection prevention in alternative health care settings.

Authors:  Elaine Flanagan; Teena Chopra; Lona Mody
Journal:  Infect Dis Clin North Am       Date:  2010-12-17       Impact factor: 5.982

9.  Community-Acquired Methicillin-Resistant Staphylococcus aureus in the Suburban Hand Surgery Patient Population.

Authors:  Marshall G Miles; Terry-Lynn Burger; Robert X Murphy
Journal:  Hand (N Y)       Date:  2009-07-07

10.  Infection control in severely burned patients.

Authors:  Yusuf Kenan Coban
Journal:  World J Crit Care Med       Date:  2012-08-04
View more