| Literature DB >> 11599756 |
Abstract
Kirschner wire (K-wire) fixation of fractures and dislocations of the hand and wrist is a common procedure. Of the 590 K-wire fixations performed on 236 patients, 36 (15.2%) experienced complications which included osteomyelitis, tendon rupture, nerve lesion, pin tract infection, pin loosening or migration. There were no deep soft-tissue pin infections or pyarthrosis. Technical failure, mainly when the procedure was performed by residents, and poor patient compliance were the major causes of complications. K-wire fixation is a simple but demanding procedure that cannot be left to an inexperienced resident. Elimination of technical failure, supervision in the operating room, close monitoring, prompt treatment upon discovery of a complication, and improvement of patient compliance can reduce the rate of complications.Entities:
Mesh:
Year: 2001 PMID: 11599756 DOI: 10.1007/s004020100279
Source DB: PubMed Journal: Arch Orthop Trauma Surg ISSN: 0936-8051 Impact factor: 3.067