Literature DB >> 11598827

Standardizing nerve crushes with a non-serrated clamp.

G M Beer1, J Steurer, V E Meyer.   

Abstract

Standardized experimental nerve crush attempts should include the number, duration, and intensity (amount of pressure) of crushes. The authors have developed a new crushing device, a clamp with which predetermined forces can be applied to nerves. This allows the exertion of different, standardized forces to crush a nerve within a scale that produces second-degree injuries. The main advantages of the clamp are that it is small, although very robust, is purely mechanical, and is easy to handle. The jaws of the clamp are not serrated, so that pressure on the nerve is uniformly transmitted. To avoid unintended nerve damage, the edges of the jaws are smoothly rounded off. The closure of the clamp is mechanized by a spring. As the spring is exchangeable, any number of different preloads are available. The force can be varied, according to different requirements, and is applicable to variantly thick nerves in any experimental animal, thus enhancing standardization, and making cross-over comparisons of experimental study results possible.

Mesh:

Year:  2001        PMID: 11598827     DOI: 10.1055/s-2001-17755

Source DB:  PubMed          Journal:  J Reconstr Microsurg        ISSN: 0743-684X            Impact factor:   2.873


  15 in total

Review 1.  Neuroprotective Effect of Natural Products on Peripheral Nerve Degeneration: A Systematic Review.

Authors:  Heitor G Araújo-Filho; Lucindo J Quintans-Júnior; André S Barreto; Jackson R G S Almeida; Rosana S S Barreto; Jullyana S S Quintans
Journal:  Neurochem Res       Date:  2015-12-08       Impact factor: 3.996

2.  Traumatic neuroma in continuity injury model in rodents.

Authors:  Jacob Daniel de Villiers Alant; Stephen William Peter Kemp; Kathleen Joy Ong Lopez Khu; Ranjan Kumar; Aubrey A Webb; Rajiv Midha
Journal:  J Neurotrauma       Date:  2011-10-19       Impact factor: 5.269

3.  Misdirection of regenerating motor axons after nerve injury and repair in the rat sciatic nerve model.

Authors:  Godard C W de Ruiter; Martijn J A Malessy; Awad O Alaid; Robert J Spinner; JaNean K Engelstad; E J Sorenson; K R Kaufman; Peter J Dyck; Anthony J Windebank
Journal:  Exp Neurol       Date:  2008-01-08       Impact factor: 5.330

4.  Reproducible mouse sciatic nerve crush and subsequent assessment of regeneration by whole mount muscle analysis.

Authors:  Andrew R Bauder; Toby A Ferguson
Journal:  J Vis Exp       Date:  2012-02-22       Impact factor: 1.355

5.  Regeneration of sciatic nerve crush injury by a hydroxyapatite nanoparticle-containing collagen type I hydrogel.

Authors:  Majid Salehi; Mahdi Naseri-Nosar; Somayeh Ebrahimi-Barough; Mohammdreza Nourani; Ahmad Vaez; Saeed Farzamfar; Jafar Ai
Journal:  J Physiol Sci       Date:  2017-09-06       Impact factor: 2.781

6.  Effect of low-level laser therapy (685 nm, 3 J/cm(2)) on functional recovery of the sciatic nerve in rats following crushing lesion.

Authors:  Mohammad Ashrafzadeh Takhtfooladi; Fatemeh Jahanbakhsh; Hamed Ashrafzadeh Takhtfooladi; Kambiz Yousefi; Amin Allahverdi
Journal:  Lasers Med Sci       Date:  2015-01-17       Impact factor: 3.161

7.  Retrograde tracing and toe spreading after experimental autologous nerve transplantation and crush injury of the sciatic nerve: a descriptive methodological study.

Authors:  Sabien Ga van Neerven; Ahmet Bozkurt; Dan Mon O'Dey; Juliane Scheffel; Arne H Boecker; Jan-Philipp Stromps; Sebastian Dunda; Gary A Brook; Norbert Pallua
Journal:  J Brachial Plex Peripher Nerve Inj       Date:  2012-04-30

8.  ErbB2 receptor over-expression improves post-traumatic peripheral nerve regeneration in adult mice.

Authors:  Giulia Ronchi; Giovanna Gambarotta; Federica Di Scipio; Paolina Salamone; Andrea E Sprio; Federica Cavallo; Isabelle Perroteau; Giovanni N Berta; Stefano Geuna
Journal:  PLoS One       Date:  2013-02-21       Impact factor: 3.240

9.  The mouse median nerve experimental model in regenerative research.

Authors:  Sara Buskbjerg Jager; Giulia Ronchi; Christian Bjerggaard Vaegter; Stefano Geuna
Journal:  Biomed Res Int       Date:  2014-08-11       Impact factor: 3.411

10.  An implantable electrical stimulator used for peripheral nerve rehabilitation in rats.

Authors:  Biyu Rui; Shangchun Guo; Bingfang Zeng; Jingwu Wang; Xin Chen
Journal:  Exp Ther Med       Date:  2013-05-13       Impact factor: 2.447

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.