Literature DB >> 11593204

The validation of volumetric real-time 3-dimensional echocardiography for the determination of left ventricular function.

J A Mondelli1, S Di Luzio, A Nagaraj, B J Kane, B Smulevitz, A V Nagaraj, R Greene, D D McPherson, V H Rigolin.   

Abstract

The objective of this study was to validate a real-time 3-dimensional echocardiography (3DE) technique for the determination of left ventricular (LV) volume and ejection fraction (EF). In 10 mongrel dogs, an electromagnetic flow (EMF) probe was placed on the aorta, and the thorax was closed. Transthoracic imaging was performed during multiple hemodynamic conditions (n = 58) with simultaneous measurement of stroke volume (SV) with the use of EMF. From the volumetric data set, LV volumes were manually traced off-line by 2 independent observers with an apical rotation method (6 planes) and a conventional method (biplane) in a subset of conditions. This tracing technique was also evaluated in 18 human subjects in whom the calculated EF values were compared with values derived by multigated radionuclide angiography (MUGA). Excellent correlation and close limits of agreement were noted between SV measured by 3DE and EMF (r = 0.93) in dogs. In comparison with EMF-derived SV, 3DE provided better correlation than the biplane method (r = 0.93 versus r = 0.61). Interobserver and intraobserver variabilities were comparable (r = 0.94 and r = 0.94, respectively). In a comparison of MUGA-derived EF values and those obtained by 3DE in human subjects, 3DE provided better correlation than the biplane method (r = 0.94 versus r = 0.85). Real-time 3DE accurately measures left ventricular volumes transthoracically over a wide range of hemodynamic conditions in dogs and accurately determines EF in humans.

Entities:  

Mesh:

Year:  2001        PMID: 11593204     DOI: 10.1067/mje.2001.115770

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  7 in total

1.  3D Echo-Based Patient-Specific Computational Left Ventricle Models to Quantify Material Properties and Stress/Strain Differences between Ventricles with and without Infarct.

Authors:  Rui Fan; Dalin Tang; Jing Yao; Chun Yang; Di Xu
Journal:  Comput Model Eng Sci       Date:  2014       Impact factor: 1.593

2.  Infarcted Left Ventricles Have Stiffer Material Properties and Lower Stiffness Variation: Three-Dimensional Echo-Based Modeling to Quantify In Vivo Ventricle Material Properties.

Authors:  Longling Fan; Jing Yao; Chun Yang; Dalin Tang; Di Xu
Journal:  J Biomech Eng       Date:  2015-06-09       Impact factor: 2.097

3.  Left atrial volume and adverse cardiovascular outcomes in unselected patients with and without CKD.

Authors:  Leia Hee; Tuan Nguyen; Melinda Whatmough; Joseph Descallar; Jack Chen; Shruti Kapila; John K French; Liza Thomas
Journal:  Clin J Am Soc Nephrol       Date:  2014-06-12       Impact factor: 8.237

4.  Comparison of echocardiographic and cardiac magnetic resonance imaging measurements of functional single ventricular volumes, mass, and ejection fraction (from the Pediatric Heart Network Fontan Cross-Sectional Study).

Authors:  Renee Margossian; Marcy L Schwartz; Ashwin Prakash; Lisa Wruck; Steven D Colan; Andrew M Atz; Timothy J Bradley; Mark A Fogel; Lynne M Hurwitz; Edward Marcus; Andrew J Powell; Beth F Printz; Michael D Puchalski; Jack Rychik; Girish Shirali; Richard Williams; Shi-Joon Yoo; Tal Geva
Journal:  Am J Cardiol       Date:  2009-06-06       Impact factor: 2.778

5.  Transthoracic 3D echocardiographic left heart chamber quantification in patients with bicuspid aortic valve disease.

Authors:  Allard T van den Hoven; Jackie S Mc-Ghie; Raluca G Chelu; Anthonie L Duijnhouwer; Vivan J M Baggen; Adriaan Coenen; Wim B Vletter; Marcel L Dijkshoorn; Annemien E van den Bosch; Jolien W Roos-Hesselink
Journal:  Int J Cardiovasc Imaging       Date:  2017-06-19       Impact factor: 2.357

6.  Accuracy of Left Ventricular Cavity Volume and Ejection Fraction for Conventional Estimation Methods and 3D Surface Fitting.

Authors:  Walter G O'Dell
Journal:  J Am Heart Assoc       Date:  2019-03-19       Impact factor: 5.501

7.  Flow-volume loops derived from three-dimensional echocardiography: a novel approach to the assessment of left ventricular hemodynamics.

Authors:  Kambiz Shahgaldi; Emil Söderqvist; Petri Gudmundsson; Reidar Winter; Jacek Nowak; Lars-Ake Brodin
Journal:  Cardiovasc Ultrasound       Date:  2008-04-04       Impact factor: 2.062

  7 in total