Evaluation of the Accusport lactate analyser.

D Bishop1.   

Abstract

It has been suggested that lactate concentrations may provide a guide to an optimal training intensity. However, lactate concentrations established during incremental exercise in the laboratory are not always indicative of what is occurring during constant-load exercise at the same intensity. Ideally, lactate concentrations should be measured during a training session and immediately reported to the athlete to ensure that the athlete is working at the desired intensity. The purpose of this investigation was, therefore, to determine the reliability and validity of a compact, portable lactate analyser (ACCUSPORT; Boeringer Mannheim, Castle Hill, Australia). A total of 224 capillary blood samples were taken from athletes who took part in routine laboratory testing. Seventy-three of these capillary blood samples were analysed in duplicate with the Accusport for determination of intraclass, single-trial reliability. Day-to-day intraclass reliability of the Accusport was assessed by analyzing known concentrations of aqueous lactate solutions on seven consecutive days. The validity of the Accusport analyser was assessed by comparing the 224 capillary blood lactate concentrations determined on the Accusport with the lactate concentration obtained using a MICRO STAT LM3 (Analox Instruments Ltd., London, UK). In addition, lactate parameters derived from the lactate concentrations obtained with the two analysers were compared. The Accusport showed high single-trial intraclass reliability (R = 0.992; Standard Error of Measurement [SE(M)] = 0.3 mmol x l(-1); n = 73) and high day-to-day intraclass reliability (R = 0.993; SE(M) = 0.4 mmol x l(-1); n = 42). Despite a strong correlation between blood lactate concentrations obtained on the two analysers (r = 0.96; n = 224) the limits of agreement were + 1.9 to - 2.2 mmol x l(-1). Although the mean values for power output, HR and lactate concentration associated with the lactate parameters were not significantly different when determined on the Accusport or Micro Stat, some individuals did record large differences between analysis methods. In summary, the results of this investigation have shown that lactate concentrations can be reliably determined within a single trial and from day-to-day using the Accusport analyser. However, for some athletes, it is not valid to compare lactate concentrations or lactate parameters determined on the Accusport with those determined using the Micro Stat LM3 lactate analyser.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11590480     DOI: 10.1055/s-2001-17611

Source DB:  PubMed          Journal:  Int J Sports Med        ISSN: 0172-4622            Impact factor:   3.118


  16 in total

1.  The anthropometrical and physiological characteristics of elite water polo players.

Authors:  Yiannis E Tsekouras; Stavros A Kavouras; Alessandro Campagna; Yiannis P Kotsis; Silia S Syntosi; Kalomira Papazoglou; Labros S Sidossis
Journal:  Eur J Appl Physiol       Date:  2005-06-23       Impact factor: 3.078

2.  Effects of short supramaximal exercise on hemorheology in sickle cell trait carriers.

Authors:  Philippe Connes; Fagnété Sara; Marie-Dominique Hardy-Dessources; Laurent Marlin; Frantz Etienne; Laurent Larifla; Christian Saint-Martin; Olivier Hue
Journal:  Eur J Appl Physiol       Date:  2006-02-28       Impact factor: 3.078

3.  Acute effects of three different circuit weight training protocols on blood lactate, heart rate, and rating of perceived exertion in recreationally active women.

Authors:  Brook L Skidmore; Margaret T Jones; Mark Blegen; Tracey D Matthews
Journal:  J Sports Sci Med       Date:  2012-12-01       Impact factor: 2.988

Review 4.  Methods of prescribing relative exercise intensity: physiological and practical considerations.

Authors:  Theresa Mann; Robert Patrick Lamberts; Michael Ian Lambert
Journal:  Sports Med       Date:  2013-07       Impact factor: 11.136

5.  The upper limit of aerobic power in humans.

Authors:  Martin Burtscher; Werner Nachbauer; Randall Wilber
Journal:  Eur J Appl Physiol       Date:  2011-03-04       Impact factor: 3.078

6.  Effects of hypoxia on cerebral and muscle haemodynamics during knee extensions in healthy subjects.

Authors:  Paulo Sergio Chagas Gomes; Cristiane Matsuura; Yagesh N Bhambhani
Journal:  Eur J Appl Physiol       Date:  2012-04-29       Impact factor: 3.078

Review 7.  The science of badminton: game characteristics, anthropometry, physiology, visual fitness and biomechanics.

Authors:  Michael Phomsoupha; Guillaume Laffaye
Journal:  Sports Med       Date:  2015-04       Impact factor: 11.136

8.  Energy cost and energy sources of a ballet dance exercise in female adolescents with different technical ability.

Authors:  Laura Guidetti; Gian Pietro Emerenziani; Maria Chiara Gallotta; Sergio Gregorio Da Silva; Carlo Baldari
Journal:  Eur J Appl Physiol       Date:  2008-03-14       Impact factor: 3.078

Review 9.  Lactate threshold concepts: how valid are they?

Authors:  Oliver Faude; Wilfried Kindermann; Tim Meyer
Journal:  Sports Med       Date:  2009       Impact factor: 11.136

10.  Role of the monocarboxylate transporter MCT1 in the uptake of lactate during active recovery.

Authors:  Rocío Cupeiro; Raúl Pérez-Prieto; Teresa Amigo; Pilar Gortázar; Carlos Redondo; Domingo González-Lamuño
Journal:  Eur J Appl Physiol       Date:  2016-03-29       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.