Immediate and six-month results of the profile of the Amplatzer septal occluder as assessed by transesophageal echocardiography.

Q L Cao1, Z D Du, A Joseph, P Koenig, M Heitschmidt, J Rhodes, Z M Hijazi.   

Abstract

Catheter closure of secundum atrial septal defect (ASD) using the Amplatzer septal occluder (ASO) is a potential alternative for open surgical repair. However, the large profile of the device obtained immediately after closure continues to raise some concerns regarding its long-term safety. To evaluate the changes in the profile of the device after being deployed, transesophageal echocardiography was performed in 70 patients (17 men and 53 women) who underwent catheter closure of ASDs immediately after and at 6-month follow-up. The median age at closure was 16 years (range 1.9 to 75) and the median size of the ASD as assessed by transesophageal echocardiography was 14 mm (range 3 to 25). The thickness (profile) of the device was assessed in the 4-chamber, short- and long-axis views of the interatrial septum, and measured at its middle and at the junction of the waist with the disc at its 2 ends. Seventy-three devices were deployed in the 70 patients. The median size of the device was 19 mm (range 8 to 34). Complete closure was achieved in 81.4% and 91.4% immediately after and at 6-months follow-up, respectively. The thickness of the device at its middle decreased from 12.2 +/- 4.3, 12.2 +/- 3.7, and 12.5 +/- 4.3 mm in the 4-chamber, short- and long-axis views to 6.5 +/- 2.0, 6.3 +/- 1.9, and 6.5 +/- 2.2 mm, respectively. The thickness of the device at its superior, inferior, anterior, and posterior edges also decreased by 41.8% +/- 14.0% to 43.7% +/- 9.8%. The changes in the thickness were related to device size. Larger devices were thicker after being deployed. We conclude that the thickness of the ASO decreases by 42% to 48% within 6 months after deployment, resulting in a lower profile.

Entities:  

Mesh:

Year:  2001        PMID: 11589842     DOI: 10.1016/s0002-9149(01)01846-x

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

Review 1.  Atrial septum defect closure device in a beating heart, from the perspective of a researcher in artificial organs.

Authors:  Yasuko Tomizawa
Journal:  J Artif Organs       Date:  2012-06-23       Impact factor: 1.731

Review 2.  Radiographic appearance of pediatric cardiovascular transcatheter devices.

Authors:  Ryan J Williams; Daniel S Levi; John W Moore; M Ines Boechat
Journal:  Pediatr Radiol       Date:  2006-08-05

3.  Right-sided pulmonary venous obstruction between a right aortic arch and an amplatzer septal occlusion device following closure of a secundum atrial septal defect.

Authors:  Kevin Hill; Karla Christian; Ann Kavanaugh-McHugh; Thomas Doyle
Journal:  Pediatr Cardiol       Date:  2009-04-15       Impact factor: 1.655

Review 4.  Challenges encountered during closure of atrial septal defects.

Authors:  W Knirsch; A Dodge-Khatami; E Valsangiacomo-Buechel; M Weiss; F Berger
Journal:  Pediatr Cardiol       Date:  2005 Mar-Apr       Impact factor: 1.655

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.