[Impact of different iodine concentrations on abdominal enhancement in biphasic multislice helical CT (MS-CT)].

B Engeroff1, L Kopka, C Harz, E Grabbe.   

Abstract

UNLABELLED: Impact of different iodine concentrations on abdominal enhancement in biphasic multislice helical CT (MS-CT).
PURPOSE: To evaluate if different iodine concentrations of a contrast material (c.m.) have an impact on abdominal enhancement in MS-CT during the arterial (AP) and portal venous phase (PVP).
MATERIALS AND METHODS: 75 patients underwent biphasic CT of the abdomen. They were assigned to three equally sized groups. For all patients a non-ionic c.m. (iopromide, Ultravist, Schering AG, Berlin) with different iodine concentrations and a constant total iodine load of 37 g with an injection flow rate of 4 ml/s was used. The volume of the c.m. differed depending on the iodine concentrations: group 1 (123 ml of 300 mgl/ml); group 2 (112 ml of 335 mgl/ml); group 3 (100 ml of 370 mgl/ml). The scan delay was optimized by using a bolus tracking device. The groups were compared concerning their mean enhancement of aorta, spleen, pancreas, and liver in the AP and PVP.
RESULTS: The comparison of the three groups showed an improved enhancement in aorta, spleen, and pancreas during the AP by using the higher c.m. concentrations. In the PVP the c.m. enhancement of aorta, liver, spleen, and pancreas was independent of the administered c.m. concentration.
CONCLUSION: Higher iodine concentrations of c.m. have a positive impact on abdominal enhancement during the AP. The concentration has no influence on the enhancement during the PVP of abdominal MS-CT.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11588683     DOI: 10.1055/s-2001-17591

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  5 in total

1.  [Multidetector computed tomography of the liver].

Authors:  W Schima; C Kulinna; A Ba-Ssalamah; T Grünberger
Journal:  Radiologe       Date:  2005-01       Impact factor: 0.635

2.  Contrast enhancement in multidetector-row computed tomography (MDCT) of the abdomen: intraindividual comparison of contrast media containing 300 mg versus 370 mg iodine per ml.

Authors:  F F Behrendt; A H Mahnken; S Keil; M Das; C Hohl; D Bauer; P Seidensticker; E Jost; J E Wildberger; R W Günther; G Mühlenbruch
Journal:  Eur Radiol       Date:  2008-01-29       Impact factor: 5.315

3.  A comparison of the use of contrast media with different iodine concentrations for multidetector CT of the kidney.

Authors:  Seung Chai Jung; Seung Hyup Kim; Jeong Yeon Cho
Journal:  Korean J Radiol       Date:  2011-09-27       Impact factor: 3.500

4.  Prospective study comparing two iodine concentrations for multidetector computed tomography of the pancreas.

Authors:  Y Liu; X Q Xu; X Z Lin; Q Song; K M Chen
Journal:  Radiol Med       Date:  2010-03-09       Impact factor: 3.469

5.  Whole-body computed tomography for multiple traumas using a triphasic injection protocol.

Authors:  Christos Loupatatzis; Sebastian Schindera; Jan Gralla; Hanno Hoppe; Jan Bittner; Ralph Schröder; Sudesh Srivastav; Harald Marcel Bonel
Journal:  Eur Radiol       Date:  2008-02-13       Impact factor: 5.315

  5 in total