Literature DB >> 11586161

Low-intensity pulsed ultrasound in the treatment of nonunions.

P A Nolte1, A van der Krans, P Patka, I M Janssen, J P Ryaby, G H Albers.   

Abstract

BACKGROUND: Low-intensity ultrasound has demonstrated an acceleration of bone healing and more profound callus formation in animal and human clinical experiments. In this study, the effect of pulsed, low-intensity ultrasound was determined in established nonunion cases.
METHODS: The enrolled cases were reviewed for the time from their last surgical procedure and evidence of no healing or progression of healing during the 3 or more months before the start of low-intensity ultrasound therapy to determine whether the cases were established nonunions. Twenty-nine cases, located in the tibia, femur, radius/ulna, scaphoid, humerus, metatarsal, and clavicle, met the criteria for established nonunions. On average, the postfracture period before the start of ultrasound treatment was 61 weeks. Initial fracture treatment was conservative in 8 cases and operative in 21 cases. Additional treatments including bone grafting, reosteosynthesis, and other surgical procedures were performed an average of 52 weeks before the start of ultrasound treatment. Daily, 20-minute applications of low-intensity ultrasound at the site of the nonunion were performed by the patients at home.
RESULTS: Twenty-five of the 29 nonunion cases (86%) healed in an average treatment time of 22 weeks (median, 17 weeks). Stratification of the healed and failed outcome for age, gender, concomitant disease, bone location, fracture age, prior last surgery interval, nonunion type, smoking habits, and fixation before and during treatment showed a significant difference only in the smoking habit strata.
CONCLUSION: Noninvasive ultrasound therapy can be useful in the treatment of challenging, established nonunions.

Entities:  

Mesh:

Year:  2001        PMID: 11586161     DOI: 10.1097/00005373-200110000-00012

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  48 in total

1.  Autologous versus allogenic bone grafts in instrumented anterior cervical discectomy and fusion: a prospective study with respect to bone union pattern.

Authors:  Petr Suchomel; Pavel Barsa; Pavel Buchvald; Adam Svobodnik; Eva Vanickova
Journal:  Eur Spine J       Date:  2004-03-20       Impact factor: 3.134

2.  Smoking increases failure rate of operation for established non-union of the scaphoid bone.

Authors:  A F Dinah; R H Vickers
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

3.  Comparison of Treatment Results for Mallet Finger Fractures in Children Between Low-Intensity Pulsed Ultrasound Stimulation and Ishiguro's Method.

Authors:  Tsuyoshi Ota; Soichiro Itoh; Yoshihiko Matsuyama
Journal:  Hand (N Y)       Date:  2017-03-08

4.  Low-intensity pulsed ultrasound induced enhanced adipogenesis of adipose-derived stem cells.

Authors:  N Fu; X Yang; K Ba; Y Fu; X Wei; Y Yue; G Li; Y Yao; J Chen; X Cai; C Liang; Y Ge; Y Lin
Journal:  Cell Prolif       Date:  2013-06       Impact factor: 6.831

5.  Osteogenic differentiation of adipose-derived stem cells prompted by low-intensity pulsed ultrasound.

Authors:  Y Yue; X Yang; X Wei; J Chen; N Fu; Y Fu; K Ba; G Li; Y Yao; C Liang; J Zhang; X Cai; M Wang
Journal:  Cell Prolif       Date:  2013-06       Impact factor: 6.831

6.  [Abstracts of the 58th Annual Meeting of the North German Orthopedic Society. June 18-20, 2009. Hamburg, Germany].

Authors: 
Journal:  Unfallchirurg       Date:  2009-06       Impact factor: 1.000

7.  Low-intensity pulsed ultrasound affects human articular chondrocytes in vitro.

Authors:  C M Korstjens; R H H van der Rijt; G H R Albers; C M Semeins; J Klein-Nulend
Journal:  Med Biol Eng Comput       Date:  2008-10-14       Impact factor: 2.602

8.  Enhancement of cell ingrowth, proliferation, and early differentiation in a three-dimensional silicon carbide scaffold using low-intensity pulsed ultrasound.

Authors:  Lin Wu; Liangjun Lin; Yi-Xian Qin
Journal:  Tissue Eng Part A       Date:  2014-07-24       Impact factor: 3.845

9.  An Evaluation of the Effect of Therapeutic Ultrasound on Healing of Mandibular Fracture.

Authors:  Kiran Patel; Sanjeev Kumar; Nishtha Kathiriya; Sonal Madan; Ankit Shah; Karthik Venkataraghavan; Mehul Jani
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2015-02-05

10.  Low-intensity pulsed ultrasound: Nonunions.

Authors:  Bernadetta G Dijkman; Sheila Sprague; Mohit Bhandari
Journal:  Indian J Orthop       Date:  2009-04       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.