Literature DB >> 11586060

Effect of pneumatic suction ring placement on intraocular pressure in cats.

B Li1.   

Abstract

PURPOSE: To determine the effect of placing a pneumatic suction ring on intraocular pressure (IOP) in the cat and to design an improved method to generate a stable elevation of IOP.
METHODS: A pneumatic suction ring was applied to the eye in cats while the IOP was monitored. Three groups of animals (10 per group) were used. A vacuum pressure of 450 mbar was applied in one step to eyes of group 1 (anesthetized) and to group 2 (euthanized) cats. In group 3 (anesthetized) cats, an initial vacuum pressure of 250 mbar was applied, followed by a vacuum of slowly increasing pressure at a rate of 5 mbar/min for a total of 40 min to 450 mbar.
RESULTS: After the one-step application of a vacuum (450 mbar) to the eyes of anesthetized cats (group 1), IOP peaked within the first minute from a basal value of 25 +/- 2 mm Hg (mean +/- SD) to 90 +/- 7 mm Hg. It then rapidly decreased to 69 +/- 2 mm Hg 5 min later and continued to decrease to 39 +/- 4 mm Hg 40 min later. This sharp peak and decline of IOP were also observed in eyes of euthanized cats (group 2). The basal IOP of these eyes was 8 +/- 1 mm Hg. It rose to 18 +/- 2 mm Hg immediately after the application of vacuum pressure (450 mbar) and returned to the basal level 5 min later. In contrast, the eyes of group 3 receiving an initial vacuum of 250 mbar followed by a 5 mbar/min vacuum increment exhibited a rapid increase in IOP and a very stable plateau (mean IOP = 62-68 mm Hg), lasting the whole study period (40 min).
CONCLUSION: IOP after a one-step application of a vacuum via a pneumatic suction ring is self-adjusting and declines rapidly over time. This decline in IOP can be overcome by a supplementary increment in vacuum pressure. Copyright 2001 S. Karger AG, Basel

Entities:  

Mesh:

Year:  2001        PMID: 11586060     DOI: 10.1159/000055680

Source DB:  PubMed          Journal:  Ophthalmic Res        ISSN: 0030-3747            Impact factor:   2.892


  2 in total

1.  Pneumatic trabeculoplasty vs latanoprost as adjunctive therapy to timolol in primary open-angle glaucoma or ocular hypertension.

Authors:  M G Uva; A Longo; M Reibaldi
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-02-27       Impact factor: 3.117

2.  Tono-Pen XL tonometry during application of a suction ring in rabbits.

Authors:  Spyridon K Charisis; Harilaos S Ginis; Georgios A Kounis; Miltiadis K Tsilimbaris
Journal:  BMC Ophthalmol       Date:  2008-07-30       Impact factor: 2.209

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.