Literature DB >> 11581596

Three-dimensional geometric comparison of partial and complete flexible mitral annuloplasty rings.

P Dagum1, T Timek, G R Green, G T Daughters, D Liang, N B Ingels, D C Miller.   

Abstract

BACKGROUND: It has previously been shown in sheep that mitral annular physiologic dynamics during the cardiac cycle are abolished by complete ring annuloplasty, but recent clinical studies suggest that flexible partial ring annuloplasty preserves normal mitral annular dynamics.
METHODS: Eight radiopaque markers were sutured equidistantly around the mitral anulus in 3 groups of sheep: no-ring control animals (n = 16); animals with a flexible Tailor partial ring annuloplasty (n = 6; St Jude Medical, Inc, St Paul, Minn); and animals with a flexible Duran ring annuloplasty (n = 7; Medtronic, Inc, Minneapolis, Minn). After 7 to 10 days' recovery, 3-dimensional marker coordinates were measured by biplane cinefluoroscopy. Mitral annular area and folding (defined as displacement of the mitral anulus from a least-squares plane) and mitral annular septal-lateral and commissure-commissure dimensions were calculated from the 3-dimensional marker coordinates throughout the cardiac cycle every 17 ms.
RESULTS: In the no-ring control group mitral annular area varied from 8.0 +/- 0.2 to 7.2 +/- 0.2 cm(2) (10% +/- 2%), and the septal-lateral and commissure-commissure dimensions varied from 27.7 +/- 0.4 to 25.9 +/- 0.4 mm (7% +/- 1%) and from 38.2 +/- 0.8 to 36.4 +/- 0.8 mm (5% +/- 1%), respectively (mean +/- standard error of the mean, P <.001 for all comparisons). In the Duran ring annuloplasty and Tailor partial ring annuloplasty groups, the anulus was fixed in size throughout the cardiac cycle (area = 4.8 +/- 0.1 and 5.3 +/- 0.3 cm(2), septal-lateral = 21.8 +/- 0.7 and 22.0 +/- 0.8 mm, and commissure-commissure = 27.7 +/- 0.7 and 31.2 +/- 1.7 mm). Mitral annular folding did not differ significantly between the control and Tailor partial ring annuloplasty groups but was dampened in the Duran ring annuloplasty group.
CONCLUSIONS: Partial Tailor flexible ring annuloplasty fixed mitral annular area and dimensions throughout the cardiac cycle in sheep; however, it preserved physiologic mitral annular folding dynamics, which might be important in terms of long-term valve function and prevention of left ventricular outflow tract obstruction.

Entities:  

Mesh:

Year:  2001        PMID: 11581596     DOI: 10.1067/mtc.2001.116313

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  15 in total

1.  The choice of mitral annuloplastic ring-beyond "surgeon's preference".

Authors:  Song Wan; Alex P W Lee; Chun-Na Jin; Randolph H L Wong; Herman H M Chan; Calvin S H Ng; Innes Y P Wan; Malcolm J Underwood
Journal:  Ann Cardiothorac Surg       Date:  2015-05

2.  Physiological mitral annular dynamics preserved after ring annuloplasty in mid-term period.

Authors:  Masaaki Ryomoto; Masataka Mitsuno; Mitsuhiro Yamamura; Hiroe Tanaka; Naosumi Sekiya; Hisashi Uemura; Ayaka Sato; Daisuke Ueda; Yuji Miyamoto
Journal:  Gen Thorac Cardiovasc Surg       Date:  2017-08-08

3.  Comparison of saddle-shape flexibility and elliptical-shape stability between Cosgrove-Edwards and Memo-3D annuloplasty rings using three-dimensional analysis software.

Authors:  Akira Tsuneto; Kiyoyuki Eishi; Takashi Miura; Kazuyoshi Tanigawa; Seiji Matsukuma; Takako Minami; Yuji Koide; Satoshi Ikeda; Hiroaki Kawano; Koji Maemura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-04-06

4.  Mitral annulus segmentation from four-dimensional ultrasound using a valve state predictor and constrained optical flow.

Authors:  Robert J Schneider; Douglas P Perrin; Nikolay V Vasilyev; Gerald R Marx; Pedro J del Nido; Robert D Howe
Journal:  Med Image Anal       Date:  2011-12-04       Impact factor: 8.545

5.  A novel shape memory alloy annuloplasty ring for minimally invasive surgery: design, fabrication, and evaluation.

Authors:  Molly F Purser; Andrew L Richards; Richard C Cook; Jason A Osborne; Denis R Cormier; Gregory D Buckner
Journal:  Ann Biomed Eng       Date:  2010-07-23       Impact factor: 3.934

6.  Mitral annulus segmentation from 3D ultrasound using graph cuts.

Authors:  Robert J Schneider; Douglas P Perrin; Nikolay V Vasilyev; Gerald R Marx; Pedro J del Nido; Robert D Howe
Journal:  IEEE Trans Med Imaging       Date:  2010-06-17       Impact factor: 10.048

7.  Flexible or rigid ring in mitral annuloplasty-do the results differ?

Authors:  Varghese Thomas Panicker; Renjith Sreekantan; Sai Suraj Kotera
Journal:  Indian J Thorac Cardiovasc Surg       Date:  2020-08-27

8.  Evaluation of a shape memory alloy reinforced annuloplasty band for minimally invasive mitral valve repair.

Authors:  Molly F Purser; Andrew L Richards; Richard C Cook; Jason A Osborne; Denis R Cormier; Gregory D Buckner
Journal:  Ann Thorac Surg       Date:  2009-10       Impact factor: 4.330

9.  Computational virtual evaluation of the effect of annuloplasty ring shape.

Authors:  Ahnryul Choi; David D McPherson; Hyunggun Kim
Journal:  Int J Numer Method Biomed Eng       Date:  2016-10-05       Impact factor: 2.747

10.  Mitral annular hinge motion contribution to changes in mitral septal-lateral dimension and annular area.

Authors:  Akinobu Itoh; Daniel B Ennis; Wolfgang Bothe; Julia C Swanson; Gaurav Krishnamurthy; Tom C Nguyen; Neil B Ingels; D Craig Miller
Journal:  J Thorac Cardiovasc Surg       Date:  2009-09-11       Impact factor: 5.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.