Literature DB >> 11580168

Monte Carlo dose verification for intensity-modulated arc therapy.

X A Li1, L Ma, S Naqvi, R Shih, C Yu.   

Abstract

Intensity-modulated arc therapy (IMAT), a technique which combines beam rotation and dynamic multileaf collimation, has been implemented in our clinic. Dosimetric errors can be created by the inability of the planning system to accurately account for the effects of tissue inhomogeneities and physical characteristics of the multileaf collimator (MLC). The objective of this study is to explore the use of Monte Carlo (MC) simulation for IMAT dose verification. The BEAM/DOSXYZ Monte Carlo system was implemented to perform dose verification for the IMAT treatment. The implementation includes the simulation of the linac head/MLC (Elekta SL20), the conversion of patient CT images and beam arrangement for 3D dose calculation, the calculation of gantry rotation and leaf motion by a series of static beams and the development of software to automate the entire MC process. The MC calculations were verified by measurements for conventional beam settings. The agreement was within 2%. The IMAT dose distributions generated by a commercial forward planning system (RenderPlan. Elekta) were compared with those calculated by the MC package. For the cases studied, discrepancies of over 10% were found between the MC and the RenderPlan dose calculations. These discrepancies were due in part to the inaccurate dose calculation of the RenderPlan system. The computation time for the IMAT MC calculation was in the range of 20-80 min on 15 Pentium-Ill computers. The MC method was also useful in verifying the beam apertures used in the IMAT treatments.

Entities:  

Mesh:

Year:  2001        PMID: 11580168     DOI: 10.1088/0031-9155/46/9/301

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Monte Carlo Modeling of the Agility MLC for IMRT and VMAT Calculations.

Authors:  Shingo Ohira; Hideki Takegawa; Masayoshi Miyazaki; Masahiko Koizumi; Teruki Teshima
Journal:  In Vivo       Date:  2020 Sep-Oct       Impact factor: 2.155

2.  Treatment planning and dosimetry of a multi-axis dynamic arc technique for prostate cancer: A comparison with IMRT.

Authors:  Kenshiro Shiraishi; Keiichi Nakagawa; Hideomi Yamashita; Naoki Nakamura; Masao Tago; Kuni Ohtomo
Journal:  Radiat Med       Date:  2006-01

3.  Monte Carlo modeling of HD120 multileaf collimator on Varian TrueBeam linear accelerator for verification of 6X and 6X FFF VMAT SABR treatment plans.

Authors:  Alanah M Bergman; Ermias Gete; Cheryl Duzenli; Tony Teke
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102

4.  The dosimetric effect of inhomogeneity correction in dynamic conformal arc stereotactic body radiation therapy for lung tumors.

Authors:  Brian D Kavanagh; Meisong Ding; Tracey E Schefter; Kelly Stuhr; Francis A Newman
Journal:  J Appl Clin Med Phys       Date:  2006-05-25       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.