Morphologic characteristics of periprosthetic tissues from hip prostheses with ceramic-ceramic couples: a comparative histologic investigation of 18 revision and 30 autopsy cases.

I Bos1, G Willmann.   

Abstract

Pseudocapsules and interface membranes from 18 revision cases having hip prostheses with ceramic-ceramic couples and 30 autopsy specimens (6 with ceramic-ceramic couples, 7 with ceramic-polyethylene combinations and 17 with metal-polyethylene combinations) were histomorphologically analyzed, including a semiquantitative grading of the wear particles and histologic changes. Unlike the revision cases, which usually showed ceramic wear particles in the adjacent tissues, only half of the autopsy cases revealed ceramic wear. As compared to the ceramic-polyethylene and metal-polyethylene couples, the alumina on alumina combinations showed a thinner synovial layer with reduced villous transformation and smaller infiltrates of macrophages and necroses, which can be explained by the absence of polyethylene wear. Metal-polyethylene couplings produced more than twice as many polyethylene wear particles with correspondingly more marked foreign body reaction than the ceramic-polyethylene couplings.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11580120     DOI: 10.1080/000164701753541970

Source DB:  PubMed          Journal:  Acta Orthop Scand        ISSN: 0001-6470


  5 in total

1.  [Damage analysis illustrated by two cases of broken ceramic inserts. Recommendations for avoiding breakages caused by handling].

Authors:  E Steinhauser; R Bader; W Mittelmeier
Journal:  Orthopade       Date:  2004-03       Impact factor: 1.087

2.  CORR Insights®: 2018 Frank Stinchfield Award: Spinopelvic Hypermobility Is Associated With an Inferior Outcome After THA: Examining the Effect of Spinal Arthrodesis.

Authors:  Laurent Sedel
Journal:  Clin Orthop Relat Res       Date:  2019-02       Impact factor: 4.176

Review 3.  How have new bearing surfaces altered the local biological reactions to byproducts of wear and modularity?

Authors:  Thomas W Bauer; Patricia A Campbell; Gretchen Hallerberg
Journal:  Clin Orthop Relat Res       Date:  2014-12       Impact factor: 4.176

4.  Is wear debris responsible for failure in alumina-on-alumina implants?

Authors:  Lucia Savarino; Nicola Baldini; Gabriela Ciapetti; Andrea Pellacani; Armando Giunti
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

Review 5.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411